Important:
In addition to these requirements, you also need to meet the requirements of both of the following sections in this chapter:
1.Suspended working platforms and manned platforms used on supported equipment, WAC 296-870-70050;2.Working platform fall protection, WAC 296-870-70055. (1) You must make sure an emergency electric operating device is provided on roof powered platforms that: (a) Can be used if either the normal operating device located on the platform or the cable connected to the platform fails; and
(b) Is mounted in a secured compartment near the hoisting machine. (2) You must make sure the secured compartment containing the emergency electric operating device: (a) Is labeled with instructions for using the emergency electric operating device; and
(b) Has means for opening the compartment mounted in: (i) A break-glass receptacle near the emergency electric operating device; or
(ii) An equivalent secure and accessible location.Wash. Admin. Code § 296-870-70060
Amended by WSR 15-23-086, Filed 11/17/2015, effective 12/18/2015Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 47.17.060. 06-19-075, § 296-870-70060, filed 9/19/06, effective 1/1/07.