25 Pa. Code § 288.253

Current through Register Vol. 54, No. 45, November 9, 2024
Section 288.253 - Standards for wells and casing of wells
(a) A monitoring well shall be cased as follows:
(1) The casing shall maintain the integrity of the monitoring well borehole and shall be constructed of material that will not react with the groundwater being monitored.
(2) The minimum casing diameter shall be 4 inches unless otherwise approved by the Department in writing.
(3) The well shall be constructed with a screen that meets the following requirements:
(i) The screen shall be factory-made.
(ii) The screen may not react with the groundwater being monitored.
(iii) The screen shall maximize open area to minimize entrance velocities and allow rapid sample recovery.
(4) The well shall be filter-packed with chemically inert clean quartz sand, silica or glass beads. The material shall be well-rounded and dimensionally stable.
(5) The casing shall be clearly visible and protrude at least 1 foot aboveground, unless the Department has approved flush mount wells.
(6) The annular space above the sampling depth shall be sealed to prevent contamination of samples and the groundwater.
(7) The casing shall be designed and constructed to prevent cross contamination between surface water and groundwater.
(8) Alternative casing designs for wells in stable formations may be approved by the Department.
(b) Monitoring well casings shall be enclosed in a protective casing that shall:
(1) Be of sufficient strength to protect the well from damage by heavy equipment and vandalism.
(2) Be installed for at least the upper 10 feet of the monitoring well, as measured from the well cap, with a maximum stick up of 3 feet, unless otherwise approved by the Department in writing.
(3) Be grouted and placed with a concrete collar at least 3 feet deep to hold it firmly in position.
(4) Be numbered for identification with a label capable of withstanding field conditions and painted in a highly visible color.
(5) Protrude above the monitoring well casing.
(6) Have a locked cap.
(7) Be made of steel or other material of equivalent strength.

25 Pa. Code § 288.253

The provisions of this §288.253 amended January 12, 2001, effective 1/13/2001, 31 Pa.B. 235.

This section cited in 25 Pa. Code § 288.123 (relating to groundwater quality description); 25 Pa. Code § 288.152 (relating to water quality monitoring plan); 25 Pa. Code § 288.251 (relating to general requirements); 25 Pa. Code § 288.256 (relating to groundwater assessment plan); 25 Pa. Code § 291.315 (relating to water quality monitoring); 25 Pa. Code § 291.416 (relating to water quality monitoring); 25 Pa. Code § 293.233 (relating to soil and groundwater monitoring); 25 Pa. Code § 295.254 (relating to soil and groundwater monitoring); 25 Pa. Code § 297.233 (relating to soil and groundwater monitoring); and 25 Pa. Code § 299.131 (relating to general requirements).