Current through Register Vol. 54, No. 45, November 9, 2024
Section 288.252 - Number, location and depth of monitoring points(a) The water quality monitoring system shall accurately characterize groundwater flow, groundwater chemistry and flow systems on the site and adjacent area. The system shall consist of the following: (1) At least one monitoring well at a point hydraulically upgradient from the disposal area in the direction of increasing static head that is capable of providing representative data of groundwater not affected by the facility, except when the facility occupies the most upgradient position in the flow system. In that case, sufficient downgradient monitoring wells shall be placed to determine the extent of adverse effects on groundwater from the facility.(2) At least three monitoring wells at points hydraulically downgradient in the direction of decreasing static head from the area in which solid waste has been or will be disposed. In addition to the downgradient wells, the Department may allow one or more springs for monitoring points if the springs are hydraulically downgradient from the area in which solid waste has been or will be disposed, if the springs are developed and protected in a manner approved by the Department and if the springs otherwise meet the requirements of this subchapter.(3) A leachate detection system for the disposal area, when required for the facility.(4) A leachate collection system for the disposal area, when required for the facility.(5) Surface water monitoring points approved by the Department.(b) The upgradient and downgradient monitoring wells shall be: (1) Sufficient in number, location and depth to be representative of water quality.(2) Located so as not to interfere with routine facility operations.(3) Located within 200 feet of the permitted disposal area, except as necessary to comply with subsection (c), and located at the points of compliance.(c) In addition to the requirements of subsection (b), upgradient monitoring wells shall be located so that they will not be affected by adverse effects on groundwater from the disposal area.(d) In addition to the requirements of subsection (b), downgradient monitoring wells shall be located so that they will provide early detection of adverse effects on groundwater from the disposal area.(e) Wells drilled under this section shall be drilled by drillers licensed under the Water Well Drillers License Act (32 P. S. §§ 645.1-645.13).(f) The well materials shall be decontaminated prior to installation.The provisions of this §288.252 amended January 12, 2001, effective 1/13/2001, 31 Pa.B. 235. This section cited in 25 Pa. Code § 288.123 (relating to groundwater quality description); 25 Pa. Code § 288.152 (relating to water quality monitoring plan); 25 Pa. Code § 288.251 (relating to general requirements); 25 Pa. Code § 288.256 (relating to groundwater assessment plan); 25 Pa. Code § 288.283 (relating to annual operation report); 25 Pa. Code § 291.315 (relating to water quality monitoring); 25 Pa. Code § 291.416 (relating to water quality monitoring); 25 Pa. Code § 293.233 (relating to soil and groundwater monitoring); 25 Pa. Code § 295.254 (relating to soil and groundwater monitoring); 25 Pa. Code § 297.233 (relating to soil and groundwater monitoring); and 25 Pa. Code § 299.131 (relating to general requirements).