The IFGC is amended by adding a chapter to read as follows:
CHAPTER 10
MANUFACTURED HOME PARK/COMMUNITY FUEL GAS EQUIPMENT AND APPLIANCE INSTALLATION
Except as otherwise permitted or required by this chapter, all fuel gas equipment and appliance installations in manufactured home parks and communities shall comply with the provisions of this code. The provisions of this chapter shall not apply to manufactured home gas piping, appliances, and equipment.
The minimum hourly volume of gas required at each manufactured home lot outlet or any section of the manufactured home gas piping system shall be calculated as shown in Table 1002. Required gas supply for buildings or other fuel gas utilization equipment and appliances connected to the manufactured home gas piping system shall be calculated as provided in this code.
Table 1002
Demand Factors for Calculating Gas Piping Systems in Manufactured Home Parks and Communities
Number of Manufactured Home Sites | Demand Factor (Btu/hr) per Manufactured Home Site | Demand Factor (Watts) per Manufactured Home Site |
1 | 125,000 | 36,638 |
2 | 117,000 | 34,293 |
3 | 104,000 | 30,482 |
4 | 96,000 | 28,138 |
5 | 92,000 | 26,965 |
6 | 87,000 | 25,500 |
7 | 83,000 | 24,327 |
8 | 81,000 | 23,741 |
9 | 79,000 | 23,155 |
10 | 77,000 | 22,569 |
11-20 | 66,000 | 19,345 |
21-30 | 62,000 | 18,172 |
31-40 | 58,000 | 17,000 |
41-60 | 55,000 | 16,121 |
Over 60 | 50,000 | 14,655 |
Gas piping shall not be installed underground beneath buildings or that portion of the manufactured home lot reserved for the location of manufactured homes, manufactured home accessory buildings or structures, concrete slabs, or automobile parking, unless installed in a gas-tight conduit complying with the following:
Exception: A gas piping lateral terminating in a manufactured home lot riser surrounded by a concrete slab shall not be required to be installed in a conduit, provided the concrete slab is entirely outside the wall line of the manufactured home, and is used for stabilizing other utility connections.
Each manufactured home lot shall have an approved gas shutoff valve installed upstream of the manufactured home lot gas outlet and located on the outlet riser at a height at least 6 inches (152 mm) above grade. Such valve shall not be located under a manufactured home. When the manufactured home lot is not in use, the outlet shall be equipped with an approved cap or plug to prevent accidental discharge of gas.
Each manufactured home lot piped for gas shall be provided with an individual outlet riser at the manufactured home lot. The manufactured home lot gas outlet shall terminate with the point of delivery in the rear third section and within 4 feet (1,219 mm) of the proposed location of the manufactured home.
All gas outlet risers, regulators, meters, valves, or other exposed equipment shall be protected from mechanical damage. Atmospherically controlled regulators shall be installed in such a manner that moisture cannot enter the regulator vent and accumulate above the diaphragm. Where the regulator vent may be obstructed due to snow and icing conditions, shields, hoods, or other suitable devices shall be provided to guard against closing the vent opening.
Meters shall not be installed in unvented or inaccessible locations or closer than 3 feet (914 mm) from sources of ignition. When meters are installed, they shall not depend on the gas outlet riser for support, but shall be adequately supported by a post or bracket placed on a firm footing, or other means providing equivalent support.
All meter installations shall be provided with a shutoff valve located adjacent to and on the inlet side of the meter. For installations utilizing a liquefied petroleum gas container, the container service valve shall serve as the shutoff valve.
The size of each section of natural gas or liquefied petroleum gas piping systems shall be determined as specified in this code.
The manufactured home park/community operator shall be responsible for maintaining all gas piping installations and equipment in good working condition.
Minn. R. agency 151, ch. 1346, ch. 8, pt. 1346.6000
Statutory Authority: MS s 16B.59; 16B.61; 16B.64; 326B.02; 326B.101; 326B.106; 326B.13