Section I-9637 - Physical Environment
A. A Level II CRC-SU shall meet the physical requirements of a Level I CRC-SU unless otherwise specified herein.
B. A Level II-CRC-SU may be located in an interior area of the hospital provided that it is immediately adjacent to the Level I CRC-SU.
1. A Level II CRC-SU may be located in a licensed offsite location of the hospital.
C. A Level II CRC-SU shall not be required to have the triage/screening rooms within the area of the Level II CRC-SU.
D. The Level II CRC-SU shall have patient rooms that meet the following requirements:
1. single occupancy rooms;
2. minimum of 100 square feet of space;
3. monolithic or tamper-proof ceilings;
4. have closet or storage space for personal belongings; and
5. electrical receptacles shall be of the safety type or protected by 5 milli ampere ground-fault-interrupters; and
6. doors that swing outward or are double hinged.
E. Electric patient beds shall not be used.
F. An electronic nurse call system is not required, but if it is included, provisions shall be made for easy removal and for covering call button outlets. The CRC-SU shall have policies and procedures to address calls where no electronic system is in place.
G. Bathrooms
1. The Level II CRC-SU shall have a minimum of two bathrooms that contain all of the following:
a. toilet;
b. shower; and
c. lavatory;
i. if the lavatory is in the patient room and not contained within the bathroom, the lavatory shall be adjacent to the bathroom.
2. If the Level II CRC-SU has more than a capacity for 12 patients, there shall be one additional bathroom for each additional capacity for four patients.
3. The bathrooms shall be outfitted as follows.
a. All plumbing and piping connections to fixtures shall be enclosed and not accessible to tampering by patients.
b. The doors on the toilet rooms shall swing out or be double hinged.
c. If mirrors are located in the toilet rooms, they shall be fabricated with laminated safety glass or protected by polycarbonate laminate, or safety screens.
d. Bathroom/toilet room hardware and accessories shall be of special design to give consideration to the prevention of injury and suicide.
4. Shower sprinkler heads shall be recessed or of a design to minimize patient tampering.
H. The Level II CRC-SU shall have a separate bathroom and a break room designated for staff use.
I. Separate and apart from the seclusion room required in a Level I CRC-SU, the Level II CRC-SU shall have a minimum of one seclusion room for each capacity for 12 patients.
1. The seclusion room in the Level II CRC-SU shall meet the same requirements specified for the seclusion room in the Level I CRC-SU.
2. The patient rooms in the Level II CRC-SU may be used as seclusion rooms provided they meet the same requirements as specified for the seclusion room in the Level I CRC-SU.
J. The Level II CRC-SU shall have separate consultation room(s) with a minimum floor space of 100 square feet each, provided at a room-to-bed ratio of one consultation room for each capacity for 12 patients. Consultation rooms within the unit shall be available for use for interviews with the patient and/or their families. The consultation room(s) shall be designed for acoustical and visual privacy.
K. The Level II CRC-SU shall have a room with a minimum of 225 square feet for group therapy, treatment team planning and conferencing.
L. The Level II CRC-SU shall have a room within the unit with a minimum of 120 square feet for examination and treatment of patients.
M. The Level II CRC-SU shall have an area for accommodation of charting, storage of records, and the storage and preparation of medications. Provisions shall be made for securing patient records and medications in this area.

La. Admin. Code tit. 48, § I-9637