The following shall be the rules for the measurement of mason work in this State:
The units of measurement shall be as follows:
For concrete foundation, the cubic yard.
For concrete floors, the superficial foot.
For dimension stone footings, the superficial foot.
For dimension stone bridge masonry, the cubic foot.
For dimension stone surface dressing, the superficial foot, extra price.
For rubble work, the perch of 24 3/4 cubic feet.
For rubble work surface dressing, the superficial foot, extra price.
For brick work, the thousand brick.
For plastering plain surfaces, the superficial yard.
For plastering cornices, the running and superficial foot.
wall, 24 3/4 cubic feet; when measured in square piles on the ground, 27 cubic
feet.
When measured in boats, 30 cubic feet.
When measured in cars, 31 1/2 cubic feet.
All stone to be measured in the wall when practicable.
Any mason work contracted for, in which the contractor agrees to furnish both
materials and labor at a stated sum per perch, shall be measured and computed
according to the following rules governing the measurement of mason work,
i.e., mason measure shall be the basis of settlement;
amount of material displaced. No allowance for rehandling. Walls to be
measured by the lineal foot in depth.
surface laid, except that no deduction be made for open tile drains.
deductions for drain or other openings under walls 2 feet, or less, in width.
Bridge masonry, compute actual cubic contents.
Surface dressing of all kinds extra.
Footings are all such foundation courses not exceeding 16 inches in height as
are wider than the body of wall above.
degrees in a vertical wall, add 2 cubic feet for each foot in height of the
wall, if the wall is battered add 2 1/2 cubic feet for each foot in height.
For each angle of more or less than 90 degrees in any wall, add 2 feet in
length of wall.
walls and add 1 cubic foot for each foot in height for each angle made by the
faces of the intersecting walls.
the girt measure.
piers connected with walls and pilasters, to be measured actual cubic contents
and add thereto 1 cubic foot for each intersection of the sides of such
projection with the wall, and 2 cubic feet for each outer corner for each foot
in height. If such projections are battered on the outer face, add 2 1/2
cubic feet instead of 2 cubic feet for each outer corner for each foot in
height.
cubic contents; if vertical, 2 cubic feet to be added for each corner for
each foot in height. If battered, add instead 2 1/2 cubic feet for each corner
for each foot in height.
pier, and compute the contents, with this sum used as the diameter, the height
to be taken as measured.
diminishing from the bottom by offsets shall be computed by rule No. 10, and
also add the sum of the areas of the level surface of the several steps
(excepting the top of the pier) multiply by 1 foot in height.
All parts of independent piers as are 6 inches or more below the surface of
the ground are to be computed actual contents, and 1 cubic foot added for each
foot in height or depth.
addition thereto allow 1 cubic foot for each foot in height.
measuring from top of sill to spring of arch, and add 3 cubic feet for each
jamb for each foot in height of opening. No deduction to be made for cut stone
trimmings and lintels.
same wall, or in adjacent walls, except in junctions of partition walls, add 2
cubic feet for each foot in height.
additional amount of masonry and add thereto 1 foot in height of wall.
wall; on gable add 1 foot in height of wall by the extreme width of gable at
its base.
than 18 inches in thickness, nor 1 foot in height.
When in the wall and practicable, the number of bricks to be estimated by
actual count; when not practicable to so count them the following rule to be
taken as a basis for estimating the number, viz.:
Every superficial foot of one-half brick (4 1/2 inches) wall to be estimated
as 6 1/2 bricks; of 1 brick (9 inches) wall at 13 bricks, etc. Increase the
number of bricks by 6 1/2 bricks for every additional half brick in thickness
of wall.
above rules, and joist holes to be charged at the rate of 15 cents each.
floor to ceiling for walls, and from wall to wall of ceiling.
and mouldings to be measured by the lineal foot on their longest extension.
Add 1 foot for each stop or mitre.
of 2 feet girt, or less, to be measured on walls by the lineal foot.
Plain cornices exceeding 2 feet girt to be measured by the superficial foot.
Add 1 lineal foot by girt for each stop or mitre.
Enriched cornices (cast work) by the lineal foot for each enrichment.
pilasters, capitals, vases, resettes, basses, pendants and niches, by the
piece.
deduction to be made for opening of 9 feet or less.
For openings of more than 9 feet square, deduct contents of openings.
For openings of more than 9 feet square, deduct contents of openings.
6 Del. C. § 5301