Distribution boxes and flow divider tees are suitable for level or nearly level ground and are installed before the soil absorption system with the goal of splitting flows equally between soil absorption system laterals. Drop boxes are suitable for sloping ground and are installed to achieve serial loading.
(a) Distribution Boxes
(b) Flow divider tees may be used in place of distribution boxes.
(c) Drop boxes are suitable for sloping ground and are installed to achieve serial loading. The drop boxes shall meet the requirements in paragraphs (a)(i through v) of this section.
020-25 Wyo. Code R. § 25-11
Amended, Eff. 7/27/2016.