Wis. Admin. Code Department of Natural Resources NR 279.34

Current through October 28, 2024
Section NR 279.34 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT)
(1) Any existing point source subject to this subcategory shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT):

BCT Effluent Limitations

Pollutant or pollutant property

Maximum for any 1 day

Average of daily values for 30 consecutive days

Metric units (kilograms per 1,000 m3 of feedstock)

BOD5

34.6

18.4

TSS

23.4

14.8

Oil and grease

11.1

5.9

pH

(1)

(1)

English units (pounds per 1,000 bbl of feedstock)

BOD5

12.1

6.5

TSS

8.3

5.25

Oil and grease

3.9

2.1

pH

(1)

(1)

1 Within the range of 6.0 to 9.0.

(2) The limits set forth in sub. (1) shall be multiplied by the following factors to calculate the maximum for any one day and maximum average of daily values for 30 consecutive days.
(a) Size factor.

1000 bbl. of feedstock per stream day

Size factor

Less than 24.9

0.73

25.0 to 49.9

0.76

50.0 to 74.9

0.83

75.0 to 99.9

0.91

100.0 to 124.9

0.99

125.0 to 149.9

1.08

150.0 or greater

1.13

(b) Process factor.

Process configuration

Process factor

Less than 4.49

0.73

4.5 to 5.49

0.8

5.5 to 5.99

0.91

6.0 to 6.49

0.99

6.5 to 6.99

1.08

7.0 to 7.49

1.17

7.5 to 7.99

1.28

8.0 to 8.49

1.39

8.5 to 8.99

1.51

9.0 to 9.49

1.65

9.5 or greater

1.72

Note: See the comprehensive example in s. NR 279.42(2) (c).

(3) The provisions of s. NR 279.14(3) apply to discharges of process wastewater pollutants attributable to ballast water by a point source subject to the provisions of this subcategory.
(4) The quantity and quality of pollutants or pollutant properties controlled by this subsection, attributable to once-through cooling water, are excluded from the discharge allowed by sub. (2).
(5) The following effluent limitations constitute the quantity and quality of pollutants or pollutant properties controlled by this subsection and attributable to contaminated runoff which may be discharged after the application of the best conventional pollutant control technology by a point source subject to this subcategory.
(a) If wastewater consists solely of contaminated runoff and is not commingled or treated with process wastewater, it may be discharged if it does not exceed 15 mg/l oil and grease based upon an analysis of any single grab or composite sample.
(b) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged may not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the department times the concentrations listed in the following table.

BCT Effluent Limitations

Pollutant or pollutant property

Maximum for any 1 day

Average of daily values for 30 consecutive days

Metric units (kilograms per 1,000 cubic meters of flow)

BOD5

48.0

26.0

TSS

33.0

21.0

Oil and grease

15.0

8.0

pH

(1)

(1)

English units (pounds per 1,000 gallons of flow)

BOD5

0.4

0.22

TSS

0.28

0.18

Oil and grease

0.13

0.067

pH

(1)

(1)

1 Within the range of 6.0 to 9.0.

Wis. Admin. Code Department of Natural Resources NR 279.34

Cr. Register, October, 1986, No. 370, eff. 11-1-86.