Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subcategory shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available:
BPT effluent limitations
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average | ||
mg/m2 (Pounds per million ft2) of area coated | ||||
Chromium . .. | 0.29 | (0.06) | 0.12 | (0.024) |
Lead ........ | 0.11 | (0.02) | 0.09 | (0.02) |
Nickel ....... | 0.98 | (0.02) | 0.7 | (0.15) |
Zinc ........ | 0.93 | (0.19) | 0.39 | (0.08) |
Aluminum . .. | 3.16 | (0.65) | 1.29 | (0.27) |
Iron ......... | 0.86 | (0.18) | 0.44 | (0.09) |
Oil and grease. | 13.86 | (2.48) | 8.32 | (1.71) |
TSS ......... | 28.42 | (5.82) | 13.86 | (2.84) |
pH .......... | (1) | (1) | (1) | (1) |
1Within the range 7.5 to 10.0.
Wis. Admin. Code Department of Natural Resources NR 262.21