Wis. Admin. Code Department of Natural Resources NR 230.672

Current through October 28, 2024
Section NR 230.672 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available

Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of BPT:

Table 78

Zinc Chloride

BPT Effluent Limitations

milligrams per liter

Pollutant or pollutant property

Maximum for any 1 day

Average of daily values for 30 consecutive days

TSS

43

25

Arsenic

3.0

1.0

Zinc

11.4

3.8

Lead

1.8

0.6

pH

(1)

(1)

(1) Within the range 6.0 to 9.0

Wis. Admin. Code Department of Natural Resources NR 230.672

Cr. Register, September, 1990, No. 417, eff. 10-1-90.