Wis. Admin. Code ATCP § 4-501.110

Current through November 25, 2024
Section 4-501.110 - Mechanical Warewashing Equipment, Wash Solution Temperature
(A) The temperature of the wash solution in spray type warewashers that use hot water to SANITIZE may not be less than:
(1) For a stationary rack, single temperature machine, 74°C (165°F); Pf
(2) For a stationary rack, dual temperature machine, 66°C (150°F); Pf
(3) For a single tank, conveyor, dual temperature machine, 71°C (160°F); Pf or
(4) For a multi-tank, conveyor, multi-temperature machine, 66°C (150°F). Pf
(B) The temperature of the wash solution in spray-type warewashers that use chemicals to SANITIZE may not be less than 49°C (120°F). Pf

Wis. Admin. Code Department of Agriculture, Trade and Consumer Protection 4-501.110

Adopted by,Register April 2015 No. 712, eff.5/1/2015.
Amended by, Register August 2016 No. 728, eff. 9/1/2016.
Adopted by, Register July 2020 No. 775, eff. 8/1/2020