EXCEPTIONS: | 1. Buildings and structures with fire hazard severity determined in Section 502 and with ignition-resistant construction classification determined in Section 503. 2. Accessory structures not exceeding 200 square feet 18.5 m2) in floor area and where located not less than 50 feet (15,240 mm) from buildings or structures containing habitable spaces. 3. Agricultural buildings located not less than 50 feet (15,240 mm) from buildings or structures containing habitable spaces. |
EXCEPTIONS: | 1. Class A roof assemblies including those with coverings of brick, masonry, or an exposed concrete roof deck. 2. Class A roof assemblies also include ferrous or copper shingles or sheets, metal sheets and shingles, clay or concrete roof tile or slate installed on noncombustible decks or ferrous, copper or metal sheets installed without a roof deck on noncombustible framing. 3. Class A roof assemblies include minimum 16 oz/sq. ft. (0.0416 kg/m2) copper sheets installed over combustible roof decks. |
EXCEPTION: | Unenclosed accessory structures attached to buildings with habitable spaces and projections, such as decks, attached to the first floor of a building, if when the structure is built with building materials at least two inches nominal depth and the area below the unenclosed accessory structure is screened with material with openings no greater than 1/4-inch maximum to prevent accumulation of combustibles and to prevent embers from coming in underneath. |
EXCEPTION: | Wall material shall be permitted to be of any material that otherwise complies with Section 501.5 when the decking surface material complies with the performance requirements of ASTM E84 with a Class B flame spread index. |
TABLE 502.1
FIRE HAZARD SEVERITY
(No change to the table)
EXCEPTION: | Not adopted. |
EXCEPTION: | Wall material shall be permitted to be of any material that otherwise complies with Section 501.5 when the decking surface material complies with the performance requirements of ASTM E84 with a Class B flame spread index. |
EXCEPTION: | Vehicle access doors. |
EXCEPTION: | The enclosure shall not be required where the underside of exposed floors and exposed structural columns, beams and supporting walls are protected as required for exterior 1-hour fire-resistance-rated construction or heavy timber construction or fire-retardant-treated wood on the exterior side. The fire-retardant-treated wood shall be labeled for exterior use and meet the requirements of Section 2303.2 of the International Building Code. |
EXCEPTION: | Not adopted. |
EXCEPTION: | Wall material shall be permitted to be of any material that otherwise complies with Section 501.5 when the decking surface material complies with the performance requirements of ASTM E84 with a Class B flame spread index. |
EXCEPTION: | Vehicle access doors. |
EXCEPTION: | The enclosure shall not be required where the underside of exposed floors and exposed structural columns, beams and supporting walls are protected as required for exterior 1-hour fire-resistance-rated construction or heavy-timber construction or fire-retardant-treated wood on the exterior side. The fire-retardant-treated wood shall be labeled for exterior use and meet the requirements of Section 2303.2 of the International Building Code. |
Wash. Admin. Code § 51-55-0500