Section 51-54A-0321 - Artificial combustible vegetation
321.1Artificial combustible vegetation on roofs and near buildings.

Artificial combustible vegetation exceeding 6 feet (1829 mm) in height and permanently installed outdoors within 5 feet (1524 mm) of a building or on the roof of a building shall comply with Section 807.4.1. The placement of artificial combustible vegetation shall also comply with Sections 806.3 and 807.4.2.

EXCEPTIONS:

1. Artificial decorative vegetation located more than 30 feet (9144 mm) from the exterior wall of a building.

2. Artificial decorative vegetation used at structures regulated by the International Residential Code.

Wash. Admin. Code § 51-54A-0321