Section 51-50-1208 - Section 1208- Interior space dimensions1208.3Dwelling unit size. Dwelling units shall have a minimum of 190 square feet (17.7 m2) of habitable space.1208.4Room area. Every dwelling unit shall have not less than one room that shall have not less than 120 square feet (11.2 m2) of net floor area. Sleeping units and other habitable rooms of a dwelling unit shall have a net floor area of not less than 70 square feet (6.5 m2). EXCEPTION: | Kitchens are not required to be of a minimum floor area. |
1208.5Efficiency dwelling units.Efficiency dwelling units shall conform to the requirements of the code except as modified herein:1. The unit's habitable space shall comply with Sections 1208.1 through 1208.4.2. The unit shall be provided with a separate closet.3. For other than accessible, Type A and Type B dwelling units, the unit shall be provided with a kitchen sink, cooking appliance and refrigerator, each having a clear working space of not less than 30 inches (762 mm) in front. Light and ventilation conforming to this4. The unit shall. be provided with a separate bathroom containing a water closet, lavatory, and bathtub or shower.Wash. Admin. Code § 51-50-1208
Amended by WSR 16-03-064, Filed 1/19/2016, effective 7/1/2016Reserved by WSR 20-01-090, Filed 12/12/2019, effective 7/1/2020Amended by WSR 22-13-094, Filed 6/14/2022, effective 7/1/2023Amended by WSR 23-23-102, Filed 11/15/2023, effective 3/16/2024Statutory Authority: RCW 19.27.031 and chapters 19.27 and 34.05 RCW. 13-04-067, § 51-50-1208, filed 2/1/13, effective 7/1/13. Statutory Authority: RCW 19.27.031 and 19.27.074. 10-03-097, § 51-50-1208, filed 1/20/10, effective 7/1/10. Statutory Authority: RCW 19.27.020, 19.27.031, 19.27.074 and chapters 19.27 and 34.05 RCW. 05-01-014, § 51-50-1208, filed 12/2/04, effective 7/1/05. Statutory Authority: RCW 19.27.031 and 19.27.074. 04-01-108, § 51-50-1208, filed 12/17/03, effective 7/1/04.