This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section C106.
AAMA | American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL 60173-4268 | |
Standard reference number | Title | Referenced in code section number |
AAMA/WDMA/CSA 101/I.S.2/A C440-17 | North American Fenestration Standard/ Specifications for Windows, Doors and Unit Skylights | ........ Table C402.4.1.1.2 |
AHAM | Association of Home Appliance Manufacturers 1111 19th Street, N.W., Suite 402 Washington, D.C. 20036 | |
Standard reference number | Title | Referenced in code section number |
ANSI/AHAM RAC-1- 2008 AHAM HRF-1-2017 | Room Air Conditioners Energy, Performance and Capacity of Household Refrigerators, Refrigerator-Freezers and Freezers | ........ Table C403.3.2 (4) ........ Table C410.1(1) |
AHRI | Air Conditioning, Heating, and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203 | |
Standard reference number | Title | Referenced in code section number |
ISO/AHRI/ASHRAE 5801-2017 | Fans - Performance Testing Using | ........ C403.8.1.1 |
ISO/AHRI/ASHRAE | ||
13256-1 (2017) | Water-source Heat Pumps - Testing and Rating for Performance - Part 1: Water-to-air and Brine-to-air Heat Pumps | ........ Table C403.3.2(14) |
ISO/AHRI/ASHRAE | ||
13256-2 (2017) | Water-source Heat Pumps - Testing and Rating for Performance - Part 2: Water-to-water and Brine-to-water Heat Pumps | ........ Table C403.3.2(14) |
210/240-2017 and 2023 | Performance Rating of Unitary Airsource Heat Pump Equipment ........ | Table C403.3.2(1), Table C403.3.2(2) |
310/380-2017 | Standard for Packaged Terminal Air Conditioners and Heat Pumps | ........ Table C403.3.2(4) |
340/360-2018 | Commercial and Industrial Unitary Air-conditioning and Heat Pump Equipment ........ | Table C403.3.2(1), Table C403.3.2(2) |
365-2009 | Commercial and Industrial Unitary Air-conditioning Condensing Units ........ | Table C403.3.2(1) |
390-2015 | Performance Rating of Single Package Vertical Air Conditioners and Heat Pumps | ........ Table C403.3.2(4) |
400-2015 | Liquid to Liquid Heat Exchangers with Addendum 2 | ........ C403.3.2 |
430-2020 | Performance Rating of Central Station Air- | ........ C403.8.1.1 |
440-19 | Room Fan Coil | ........ C403.8.1.1, C403.10.3 |
460-05 | Performance Rating Remote Mechanical Draft Air-cooled Refrigerant Condensers | ........ Table C403.3.2(7) |
550/590-2018 | Water Chilling Packages Using the Vapor Compression Cycle-with Addenda ........ | C403.3.2.3, Table C403.3.2(3), Table C403.3.2(15) |
560-2018 | Absorption Water Chilling and Water-heating Packages ........ | Table C403.3.2(3) |
910-2014 | Performance Rating of Indoor Pool ........ | Table C403.3.2(11) |
920-2015 | Performance Rating of DX-Dedicated Outdoor Air System Units | ........C202, Table C403.3.2(12), Table C403.3.2 (13) |
1160-2014 | Performance Rating of Heat Pump Pool Heaters ........ | Table C404.2, C404.11.1 |
1200-2013 | Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets ........ | C410.1, Table C410.1(1), Table C410.1(2) |
1230-2014 | Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment (with Addendum 1). | Table C403.3.2(9) |
1250-2014 | Standard for Performance Rating in Walk-in Coolers and Freezers ........ | Table C410.2.1(3) |
AMCA | Air Movement and Control Association International 30 West University Drive Arlington Heights, IL 60004-1806 | |
Standard reference number | Title | Referenced in code section number |
205-12 | Energy Efficiency Classification for Fans ........ | C403.8.3 |
208-2018 | Calculation of the Fan Energy Index ........ | C403.8.1.1, C403.8.3 |
210-2016 | Laboratory Methods of Testing Fans for Certified Aerodynamic Performance Rating ........ | C403.8.1.1 |
220-19 | Laboratory Methods for Testing Air Curtain Units for Aerodynamic Performance Rating ........ | C402.5.7 |
230-15 | Laboratory Methods of Testing Air Circulating Fans for Rating and Certification ........ | C403.9 |
500D-18 | Laboratory Methods for Testing Dampers for Rating ........ | C402.4.5.1, C402.4.5.2 |
ANSI | American National Standards Institute 25 West 43rd Street Fourth Floor New York, NY 10036 | |
Standard reference number | Title | Referenced in code section number |
ANSI/AMCA 208-2018 | Calculation of the Fan Energy Index ........ | C403.8.1.1 |
ANSI/AMCA 210-16/ASHRAE 51-16 | Laboratory Methods of Testing Fans for Certified Aerodynamic Performance Rating ........ | C403.8.1.1 |
ANSI/ASME A17.1-2010 | Safety code for elevators and escalators ........ | C405.12.1 |
ANSI/CTA 2045-A-2018 | Modular Communications Interface for Energy Management ........ | C404.14 |
ANSI/CTA 2045-B-2021 | Modular Communications Interface for Energy Management ........ | C404.14 |
Z21.10.3/CSA 4.3- 17 | Gas Water Heaters, Volume III-Storage Water Heaters with Input Ratings Above 75,000 Btu per Hour, Circulating Tank and Instantaneous ........ | Table C404.2 |
Z21.47/CSA 2.3-16 | Gas-fired Central Furnaces ........ | Table C403.3.2(5) |
Z83.8/CSA 2.6-16 | Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters and Gas-fired Duct Furnaces ........ | Table C403.3.2(5) |
APSP | The Association of Pool and Spa Professionals 2111 Eisenhower Avenue Alexandria, VA 22314 | |
Standard reference number | Title | Referenced in code section number |
14-2019 | American National Standards for Portable Electric Spa Efficiency ........ | C404.12 |
ASABE | American Society of Agricultural and Biological Engineers 2950 Niles Road St. Joseph, MI 49085 | |
Standard reference number | Title | Referenced in code section |
S640-2017 | Quantities and Units of Electromagnetic Radiation for Plants (Photosynthetic Organisms) ......... | C405.3 |
ASHRAE | American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. 1791 Tullie Circle, N.E. Atlanta, GA 30329-2305 | |
Standard reference number | Title | Referenced in code section number |
ANSI/ASHRAE/ACCA Standard 127-2007 | Method of Testing for Rating Computer and Data Processing Room Unitary Air Conditioners ........ | C403.5 |
Standard 183- RA2017 | Peak Cooling and Heating Load Calculations in Buildings, Except Low-rise Residential Buildings ........ | C403.1.2 |
ASHRAE- 2020 | ASHRAE HVAC Systems and Equipment Handbook- 2020 ........ | C403.1.2 |
ISO/AHRI/ASHRAE 13256-1 2012) | Water-source Heat Pumps-Testing and Rating for Performance-Part 1: Water-to-air and Brine-to-air Heat Pumps ........ | Table C403.3.2(14) |
ISO/AHRI/ASHRAE 13256-2 2012) | Water-source Heat Pumps-Testing and Rating for Performance-Part 2: Water-to-water and Brine-to-water Heat Pumps ........ | Table C403.3.2(14) |
90.1-2019 | Energy Standard for Buildings Except Low-rise Residential Buildings (ANSI/ASHRAE/IESNA 90.1-2019)(with addendum af) ........ | Table C402.1.3, Table C402.1.4, C406.2 |
90.4-2019 | Energy Standard for Data Centers (with Addenda a, b, d, e) ........ | C403.1.3 |
146-2011 | Testing and Rating Pool Heaters ........ | Table C404.2 |
ASME | American Society of Mechanical Engineers Two Park Avenue New York, NY 10016-5990 | |
Standard reference number | Title | Referenced in code section number |
ASME A17.1/CSA B44- 2019 | Safety Code for Elevators and Escalators ........ | C405.9.2 |
BPVC Section IV-2021 | Boiler and Pressure Vessel Code, Section IV-Rules for Construction of Heating Boilers ........ | C404.14 |
BPVC Section X-2021 | Boiler and Pressure Vessel Code, Section X-Fiber-Reinforced Plastic Pressure Vessels ........ | C404.14 |
ASTM | ASTM International 100 Barr Harbor Drive West Conshohocken, PA 19428-2859 | |
Standard reference number | Title | Referenced in code section number |
C 90-206A | Specification for Load-bearing Concrete Masonry Units ........ | Table C402.1.3 |
C518-17 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus ........ | Table C403.10.1.1 |
C1363-11 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus ........ | C303.1.4.1, Table C402.1.4 |
C1363-11 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus ........ | C303.1.4.1, Table C402.1.4, C402.2.7 |
C 1371-15 | Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers ........ | Table C402.4 |
C 1549-09 | Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using A Portable Solar Reflectometer ........ | Table C402.4 |
D 1003-13 | Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics ........ | C402.4.2.2 |
E 283-04 (2012) | Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen ........ | C402.5.8 |
E 408-13 | Test Methods for Total Normal Emittance of Surfaces Using Inspection-meter Techniques ........ | Table C402.3 |
E 779- 2018 | Standard Test Method for Determining Air Leakage Rate by Fan Pressurization ........ | C402.5.1.2.3 |
E 903-12 | Standard Test Method Solar Absorptance, Reflectance and Transmittance of Materials Using Integrating Spheres (Withdrawn 2005) ........ | Table C402.4 |
E 1677-11 | Standard Specification for an Air-retarder (AR) Material or System for Low-rise Framed Building Walls ........ | C402.5.1.2.2 |
E 1827-2011(2017) | Standard Test Methods for Determining Airtightness of Building Using an Orifice Blower Door ......... | C402.5.2, C402.5.3 |
E 1918-06 (2015) | Standard Test Method for Measuring Solar Reflectance of Horizontal or Low-sloped Surfaces in the Field ........ | Table C402.4 |
E 1980-11 | Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-sloped Opaque Surfaces ........ | Table C402.2.1.1 |
E 2178-13 | Standard Test Method for Air Permanence of Building Materials ........ | C402.4 |
E 2357-11 | Standard Test Method for Determining Air Leakage of Air Barrier Assemblies ........ | C402.5.1.2.2 |
F 1281-2017 | Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL_PEX) Pressure Pipe ........ | Table C404.5.2.1 |
CSA | Canadian Standards Association 5060 Spectrum Way Mississauga, Ontario, Canada L4W 5N6 | |
Standard reference number | Title | Referenced in code section number |
AAMA/WDMA/CSA 101/I.S.2/A440-11 | North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights ........ | Table C402.4.2 |
CSA B55.1-2015 | Test Method for Measuring Efficiency and Pressure Loss of DWHR Units ........ | C404.10 |
CSA B55.2-2015 | Drain Water Heat Recovery Units ........ | C404.10 |
CTA | Consumer Technology Association 1919 S Eads Street Arlington, VA 22202 | |
Standard reference number | Title | Referenced in code section |
ANSI/CTA 2045-A-2018 | Modular Communications Interface for Energy Management. ........ | C404.14 |
ANSI/CTA 2045-B-2021 | Modular Communications Interface for Energy Management. ........ | C404.14 |
CTI | Cooling Technology Institute 2611 FM 1960 West, Suite A-101 Houston, TX 77068 | |
Standard reference number | Title | Referenced in code section number |
ATC 105-2019 | Acceptance Test Code for Water Cooling Tower ........ | Table C403.3.2 (7) |
ATC 105DS-2018 | Acceptance Test Code for Dry Fluid Coolers ........ | Table C403.3.2(7) |
ATC 105S-11 | Acceptance Test Code for Closed Circuit Cooling Towers ........ | Table C403.3.2 (7) |
ATC 106-11 | Acceptance Test Code for Mechanical Draft Evaporative Vapor Condensers ........ | Table C403.3.2 (7) |
STD 201-17 | Standard for Certification of Water Cooling Towers Thermal Performances ........ | Table C403.3.2 (7) |
DASMA | Door and Access Systems Manufacturers Association 1300 Sumner Avenue Cleveland, OH 44115-2851 | |
Standard reference number | Title | Referenced in code section number |
105-17 | Test Method for Thermal Transmittance and Air Infiltration of Garage Doors ........ | Table C402.4.2 |
DOE | U.S. Department of Energy c/o Superintendent of Documents U.S. Government Printing Office Washington, D.C. 20402-9325 | |
Standard reference number | Title | Referenced in code section number |
10 C.F.R., Part 430-2015 | Energy Conservation Program for Consumer Products: Test Procedures and Certification and Enforcement Requirement for Plumbing Products; and Certification and Enforcement Requirements for Residential Appliances; Final Rule ........ | Table C403.3.2(1), Table C403.3.2(2), Table C403.3.2(5), Table C403.3.2(6), Table C403.3.2(14), Table C404.2 |
10 C.F.R., Part 431-2015 | Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures and Efficiency Standards; Final Rules ........ | Table C403.3.2(6), C403.8.4, C403.11, Table C403.11, C403.11.2, C405.7, Table C405.7, C405.8, Table C405.8(1), Table C405.8(2), Table C405.8(3) |
HVI | Home Ventilating Institute 1740 Dell Range Blvd., Ste. H, PMB 450 Cheyenne, WY 82009 | |
Standard reference number | Title | Referenced in code section |
920-2020 | Product Performance Certification Procedure Including Verification and Challenge ........ | C403.3.5.1, C403.3.6 |
IAPMO | International Association of Plumbing and Mechanical Officials 4755 E. Philadelphia Street Ontario, CA 91761 | |
Standard reference number | Title | Referenced in code section number |
UPC-2021 | Uniform Plumbing Code ........ | C201.3, C501.2 |
ICC | International Code Council, Inc. 500 New Jersey Avenue, N.W., 6th Floor Washington, D.C. 20001 | |
Standard reference number | Title | Referenced in code section number |
IBC-21 | International Building Code ........ | C201.3, C303.2, C402.4.3, C501.2 |
ICC 500-2020 | Standard for the Design and Construction of ........ | C402.4.2 |
IFC-21 | International Fire Code ........ | C201.3, C501.2 |
IFGC-21 | International Fuel Gas Code ........ | C201.3, C501.2 |
IMC-21 | International Mechanical Code ........ | C106.3, C201.3, C402.5.3, C403.2.2.1, C403.2.2.2, C403.3.5, C403.3.5.1, C403.6.1, C403.6.5, C403.6.10, C403.7.1, C403.7.2, C403.7.5, C403.7.5.1, C403.7.6, C403.7.7.3, C403.7.8.1, C403.7.8.4, C403.8.4, C403.8.5.1, Table C403.10.1, C403.10.1.2, Table C403.10.1.2, C403.10.2.2, C403.12, C406.6, C408.2.2.1, C501.2 |
IEEE | The Institute of Electrical and Electronic Engineers, Inc. 3 Park Avenue New York, NY 10016 | |
Standard reference number | Title | Referenced in code section number |
IEEE 515.1-2012 | IEEE Standard for the Testing, Design, Installation and Maintenance of Electrical Resistance Trace Heating for Commercial Applications ........ | C404.6.2 |
IES | Illuminating Engineering Society 120 Wall Street, 17th Floor New York, NY 10005-4001 | |
Standard reference number | Title | Referenced in code section number |
ANSI/ASHRAE/IESNA 90.1-2019 | Energy Standard for Buildings Except Low-rise Residential Buildings ........ | Table C402.1.3, Table C402.1.4, Table C407.5.1 |
ISO | International Organization for Standardization 1, rue de Varembe, Case postale 56, CH-1211 Geneva, Switzerland | |
Standard reference number | Title | Referenced in code section number |
ISO/AHRI/ASHRAE 13256-1 (2017) | Water-Source Heat Pumps-Testing and Ratingor Performance-Part 1: Water-to-air and Brine-to-air Heat Pumps ........ | C403.3.2 (14) |
ISO/AHRI/ASHRAE 13256-2 (2017) | Water-Source Heat Pumps-Testing and Rating for Performance-Part 2: Water-to-water and Brine-to-water Heat Pumps ........ | C403.3.2 (14) |
25745-2:2015 | Energy Performance of Lifts, Escalators and Moving Walks-Part 2: Energy Calculation and Classification for Lifts (Elevators) ........ | C406.2.14 |
NEEA | Northwest Energy Efficiency Alliance 421 SW 6th Ave. Suite 600 Portland, OR 97204 | |
Standard reference number | Title | Referenced in code section |
AWHS Vers. 8.0-2022 | Advanced Water Heating Specification ........ | C404.2.1 |
NEMA | National Electric Manufacturers Association 1300 North 17th Street Suite 1752 Rosslyn, VA 22209 | |
Standard reference number | Title | Referenced in code section number |
ANSI/NEMA WD 6-2016 MGI- 2016 | Wiring Devices-Dimensional Specifications ........ Motors and Generators ........ | C405.12 C202 |
TP-1-2002 | Guide for Determining Energy Efficiency for Distribution Transformers ........ | C405.9 |
NFRC | National Fenestration Rating Council, Inc. 6305 Ivy Lane, Suite 140 Greenbelt, MD 20770 | |
Standard reference number | Title | Referenced in code section number |
100-2020 | Procedure for Determining Fenestration Product U-factors ........ | C303.1.2, C402.2.2 |
200-2020 | Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence ........ | C303.1.3, C402.4.1.1 |
202-2017 | Procedure for Determining Fenestration Product Visible Transmittance at Normal Incidence ........ | C202 |
NFRC 203-2017 | Procedure for Determining Visible Transmittance of Tubular Daylighting Devices ........ | C202, C402.4.2 |
400-2017 | Procedure for Determining Fenestration Product Air Leakage ........ | Table C402.4.2 |
SMACNA | Sheet Metal and Air Conditioning Contractors National Association, Inc. 4021 Lafayette Center Drive Chantilly, VA 20151-1209 | |
Standard reference number | Title | Referenced in code section number |
SMACNA-2012 | HVAC Air Duct Leakage Test Manual ........ | C403.10.2.3 |
UL | Underwriters Laboratories 333 Pfingsten Road Northbrook, IL 60062-2096 | |
Standard reference number | Title | Referenced in code section number |
710-12 | Exhaust Hoods for Commercial Cooking Equipment ........ | C403.7.5 |
727- 18 | Oil-fired Central Furnaces-with Revisions through April 2010 ........ | Table C403.3.2(4), Table C403.3.2(5) |
731- 18 | Oil-fired Unit Heaters-with Revisions through April 2010 ........ | Table C403.3.2(5) |
US-FTC | United States-Federal Trade Commission 600 Pennsylvania Avenue N.W. Washington, D.C. 20580 | |
Standard reference number | Title | Referenced in code section number |
C.F.R. Title 16 (2015) | R-value Rule ........ | C303.1.4 |
WDMA | Window and Door Manufacturers Association 1400 East Touhy Avenue, Suite 470 Des Plaines, IL 60018 | |
Standard reference number | Title | Referenced in code section number |
AAMA/WDMA/CSA 101/I.S.2/A440-17 | North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights ........ | Table C402.4.2 |
Wash. Admin. Code § 51-11C-600000
Reviser's note: The brackets and enclosed material in the text of the above section occurred in the copy filed by the agency and appear in the Register pursuant to the requirements of RCW 34.08.040.