Wash. Admin. Code § 296-876-40020

Current through Register Vol. 24-23, December 1, 2024
Section 296-876-40020 - Set-up
(1) You must set up non-self-supporting ladders at a safe angle. The ladder is set at the proper angle when the horizontal distance from the top support to the foot of the ladder is approximately one-quarter the working length of the ladder.
(2) You must set up job-made ladders with spliced side rails so that the horizontal distance from the top support to the foot of the ladder is not greater than one-eighth the working length of the ladder.
(3) You must set up the top of a nonself-supporting ladder so that both side rails are supported, unless the ladder is equipped with a single support attachment.

Click to view image

Wash. Admin. Code § 296-876-40020

Amended by WSR 14-09-095, filed 4/22/14, effective 7/1/2014
Amended by WSR 20-09-146, Filed 4/21/2020, effective 10/1/2020

Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-20-068, § 296-876-40020, filed 10/4/05, effective 1/1/06.