Wash. Admin. Code § 296-874-20020

Current through Register Vol. 24-23, December 1, 2024
Section 296-874-20020 - Provide safe access to scaffolds
(1) You must provide scaffold platforms more than two feet (0.6 m) above or below a point of access with at least one of the following means of access:
(a) Portable, hook-on, or attachable ladder;
(b) Stairway-type ladder;
(c) Ladder stand;
(d) Stair tower (scaffold stairway or tower);
(e) Ramp;
(f) Walkway;
(g) Integral prefabricated scaffold access;
(h) Direct access from another scaffold, structure, personnel hoist, or similar surface.
(2) You must make sure crossbraces are not used as a means of access.

Reference:

For requirements about integral prefabricated scaffold access, go to WAC 296-874-40020.

Wash. Admin. Code § 296-874-20020

Amended by WSR 15-23-086, Filed 11/17/2015, effective 12/18/2015

Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-01-054, § 296-874-20020, filed 12/7/04, effective 3/1/05.