Wash. Admin. Code § 296-806-48072

Current through Register Vol. 24-23, December 1, 2024
Section 296-806-48072 - Provide kickback protection on planers running stock of varied thicknesses

You must provide kickback protection on planers running stock of varied thicknesses at the same time by providing either:

(1) Sectional feed rolls that provide feeding contact pressure on the stock;

or

(2) Suitable nonkickback fingers at the infeed end of each section.

Note: The sectional feed rolls need to have sufficient yield in their construction to provide contact pressure on any thickness of stock the machine is capable of processing.

Wash. Admin. Code § 296-806-48072

Amended by WSR 15-24-102, Filed 12/1/2015, effective 1/5/2016

Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. 04-14-028, § 296-806-48072, filed 6/29/04, effective 1/1/05.