Wash. Admin. Code § 296-806-20054

Current through Register Vol. 24-23, December 1, 2024
Section 296-806-20054 - Make sure devices used with barrier guards meet these requirements

Important:

All devices must meet the general requirements for devices found in. Make sure devices meet these requirements, WAC 296-806-20044.

(1) You must make sure movable barrier devices:
(a) Return to the open position if they encounter an obstruction while enclosing the hazardous area.
(b) Are designed so the operator or others cannot reach the hazard by reaching over, under, around or through the device when it is in the closed position.
(2) You must make sure interlocks used with barrier guards do all of the following:
(a) Stop hazardous motion of machines when interlocks are open.
(b) Are not easily bypassed.
(c) Are designed and installed so that closing the interlocks will not cause a hazard to employees.

Wash. Admin. Code § 296-806-20054

Amended by WSR 15-24-102, Filed 12/1/2015, effective 1/5/2016

Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. 04-14-028, § 296-806-20054, filed 6/29/04, effective 1/1/05.