Section 296-56-60217 - Spiral stairways
(1) You must meet the following requirements for spiral stairways :
(a) Stairways must conform to the minimum dimensions of Figure F-1;

Figure F-1

Click Here To View Image

Spiral Stairway Minimum Dimensions
A (Half-tread width) B
Normal use by employees ...... 11 inches (27.9 cm) 6 inches (15.2 cm)
Limited access . . . 9 inches (22.9 cm) 5 inches (12.7 cm)

(b) Stairway risers must be uniform and shall range from six and one-half to ten and one-half inches (16.5 to 26.67 cm) in height;
(c) Minimum loading capability be one hundred pounds per square foot (445 N), and minimum tread center concentrated loading shall be three hundred pounds (1334 N);
(d) Railing must conform to the requirements of WAC 296-56-60123(3). If balusters are used, there must be a minimum of one per tread. Handrails must be a minimum of one and one-fourth inches (3.18 cm) in outside diameter; and
(e) Vertical clearance must be at least six feet, six inches (1.98 m) above the top step.
(2) You must maintain spiral stairways in safe condition.

Wash. Admin. Code § 296-56-60217

Amended by WSR 15-24-102, Filed 12/1/2015, effective 1/5/2016

Statutory Authority: RCW 49.17.010, [49.17].040, and[49.17].050 . 00-21-103, § 296-56-60217, filed 10/18/00, effective 2/1/01. Statutory Authority: RCW 49.17.040. 99-02-024, § 296-56-60217, filed 12/30/98, effective 3/30/99. Statutory Authority: RCW 49.17.040 and 49.17.050. 86-03-064 (Order 86-02), § 296-56-60217, filed 1/17/86; 85-10-004 (Order 85-09), § 296-56-60217, filed 4/19/85; 85-01-022 (Order 84-24), § 296-56-60217, filed 12/11/84.