Goggles should also be worn during arc welding or cutting operations to provide protection from injurious rays from adjacent work, and from flying objects. The goggles may have either clear or colored glass, depending upon the amount of exposure to adjacent welding operations. You must provide helpers or attendants with proper eye protection.
Filter Lenses for Protection against Radiant Energy
Welding operation | Electrode Size 1/32 (inches) | Minimum protective arc current | Shade number |
Shielded metal arc welding | Less than 3 | Less than 60 | 10 |
3-5 | 60-160 | 10 | |
5-8 | 160-250 | 12 | |
More than 8 | 250-550 | 14 | |
Gas shielded arc welding (nonfer-rous) | 2, 3, 4, 5 | 11 | |
Gas shielded arc welding (ferrous) | 2, 3, 4, 5 | 12 | |
Gas metal arc welding | Less than 60 | 7 | |
60-160 | 10 | ||
160-250 | 10 | ||
250-500 | 10 | ||
Flux cored arc welding | Less than 60 | 7 | |
60-160 | 10 | ||
160-250 | 10 | ||
250-500 | 10 | ||
Gas tungsten arc welding | Less than 50 | 8 | |
50-150 | 8 | ||
150-500 | 10 | ||
Air carbon light Light | Less than 500 | 10 | |
Arc cutting heavy | 500-1000 | 11 | |
Carbon arc welding | 14 | ||
Plasma arc welding | Less than 20 | 6 | |
20-100 | 8 | ||
100-400 | 10 | ||
400-800 | 11 | ||
Plasma arc cutting | Less than 300 (light) | 8 | |
300-400 (medium) | 9 | ||
400-800 (heavy) | 10 | ||
Atomic hydrogen welding | 10-14 | ||
Torch soldering | 2 | ||
Torch brazing | 3 or 4 | ||
Gas welding | |||
Light | Under 1/8 | Under 3.2 | 3 or 4 |
Note: In gas welding or oxygen cutting where the torch produces a high yellow light, it is desirable to use a filter or lens that absorbs the yellow or sodium line in the visible light of the operation.
Wash. Admin. Code § 296-24-70003
Statutory Authority: RCW 49.17.010, [49.17].040, and[49.17].050 . 01-11-038, § 296-24-70003, filed 5/9/01, effective 9/1/01; Order 73-5, § 296-24-70003, filed 5/9/73 and Order 73-4, § 296-24-70003, filed 5/7/73.