Table 29
Hardware Inspection
For all hardware, inspect for the following: |
* Missing or illegible identification. |
* For shackles, missing or illegible manufacturer's name or trademark and/or rated load identification. |
* Indications of heat damage, including weld spatter or arc strikes. |
* Excessive pitting or corrosion. |
* Load bearing components that are: |
- Bent. |
- Twisted. |
- Distorted. |
- Stretched. |
- Elongated. |
- Cracked. |
- Broken. |
* Excessive nicks or gouges. For riggings blocks, excessive nicks, gouges and wear. |
* 10% reduction of the original or catalog dimension at any point. For shackles, this includes at any point around the body or pin. |
* Excessive thread damage or wear, where applicable. |
* Evidence of unauthorized welding or modification. |
* Any other conditions that cause doubt as to the safety of continued use. |
* On shackles, also inspect for incomplete pin engagement. |
* On swivels and swivel hoist rings, check for lack of ability to freely rotate or pivot. |
* On compression hardware, also check for: |
- Unauthorized replacement components. |
- Insufficient number of wire rope clips. |
- Improperly tightened wire rope clips. |
- Damaged wire rope. |
- Indications of wire rope slippage. |
- Improper assembly. |
* On swivels, check for loose or missing nuts, bolts, cotter pins, snap rings, or other fasteners and retaining devices. |
* On blocks check for: |
- Loose or missing nuts, bolts, cotter pins, snap rings, or other fasteners and retaining devices. |
- Misalignment or wobble in sheaves. |
- Excessive sheave groove corrugation or wear. |
Wash. Admin. Code § 296-155-56100
Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060 and chapter 49.17 RCW, and 29 C.F.R. 1926, Subpart CC. 13-02-068, § 296-155-56100, filed 12/31/12, effective 2/1/13. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.440, 49.17.060, and 29 C.F.R. 1926, Subpart CC. 12-01-086, § 296-155-56100, filed 12/20/11, effective 2/1/12.