Wash. Admin. Code § 296-150M-0302

Current through Register Vol. 24-23, December 1, 2024
Section 296-150M-0302 - What are some examples of work to manufactured or mobile homes that either require or do not require a permit and inspection?

TYPE OF WORKALTERATION PERMIT AND INSPECTION REQUIRED?
YesNo
(1) Air Conditioner/Heat Pump
(a) New installationX
(b) ReplacementX
(c) Reconnection after moving homeX
(d) RepairX
(e) Adjustment and/or maintenanceX
(2) Bottom Board - RepairX
(3) Clothes Washer
(a) New installationX
(b) ReplacementX
(c) Repair with approved partsX
(d) Adjustment and/or maintenanceX
(4) Clothes Dryer (Electric)
(a) New installation (Prewired electrical)X
(b) ReplacementX
(c) Repair with approved partsX
(d) Adjustment and/or maintenanceX
(e) Replacement with gas clothes dryer when modifications to electrical or gas systems are performedX
(5) Clothes Dryer (Gas)
(a) New installation (Preplumbed gas)X
(b) ReplacementX
(c) Repair with approved partsX
(d) Adjustment and/or maintenanceX
(e) Replacement with electric clothes dryer when modifications to electrical or gas systems are performedX
(6) Dishwasher
(a) New installationX
(b) Replacement
(i) Cord connectedX
(ii) Direct wiredX
(c) RepairX
(d) Adjustment and/or maintenanceX
(7) Doors (Interior and Exterior)
(a) Additional*X
(b) Replacement of door that fits into the same openingX
(8) Electrical
(a) Replacing main electrical panel******X
(b) Adding circuitsX
(c) Extending existing circuit(s)X
(d) Replacing lighting fixtures****X
(e) Replacing circuit breakers/fusesX
(f) Replacing switches, receptacles, light bulbs, fluorescent tubes and glass or plastic shadesX
(g) Repairing bath exhaust fansX
(h) Repairing fans in kitchen range hoodsX
(9) Exterior Finish
(a) PaintingX
(b) Replacement of sidingX
(10) Furnace (Electric)
(a) New installationX
(b) ReplacementX
(c) RepairX
(d) Adjustment and/or maintenanceX
(e) Replacement with gas furnaceX
(11) Furnace (Gas)
(a) New installationX
(b) ReplacementX
(c) RepairX
(d) Change from LP Gas to Natural Gas or from Natural Gas to LP gas per its listingX
(e) Adjustment and/or maintenanceX
(f) Replacement with electric furnaceX
(12) Gas Lines
(a) New installationX
(b) Extend existing gas lineX
(c) RepairX
(13) Interior
(a) Painting, wall papering and similar finish workX
(b) Replacement or addition of curtains, drapes, blinds, window shades and other window coveringsX
(c) Replacement of carpeting and other floor-covering materials with similar materialsX
(14) Microwave Oven (Over range)
(a) New installation when electrical system modifications are performedX
(b) ReplacementX
(c) RepairX
(d) Adjustment and/or maintenanceX
(15) Microwave Oven (Countertop)X
(16) Pellet Stove
(a) New installationX
(b) ReplacementX
(c) RepairX
(d) Adjustment and/or maintenanceX
(17) Plumbing
(a) Adding plumbing fixtures***X
(b) Repairing damage***X
(c) Replacing fixtures***X
(d) Repairing fixtures***X
(e) Replacement/repair of shower doors and curtainsX
(18) Range/Cook Top/Eye Level Oven (Electric)
(a) Replacement
(i) Cord connectedX
(ii) Direct wiredX
(b) Repair with approved partsX
(c) Adjustment and/or maintenanceX
(d) Replacement with gas appliance(s)X
(19) Range/Cook Top/Eye Level Oven (Gas)
(a) New installationX
(b) ReplacementX
(c) Repair with approved partsX
(d) Adjustment and/or maintenanceX
(e) Replacement with electric appliance(s)X
(20) Roofing
(a) ReroofingX
(b) Applying liquid or mastic roof sealant to a metal roofX
(c) Repair of damaged composition shinglesX
(21) Structural changes
(a) Adding a dormer*X
(b) Truss repairs*X
(c) Add opening in wall**X
(d) Add gypsum board to walls or ceilingsX
(e) Repair or replacing floor decking/joistsX
(22) Water Heater (Electric)
(a) Replacement w/electric water heaterX
(b) RepairX
(c) Adjustment and/or maintenanceX
(d) Replacement with gas water heaterX
(23) Water Heater (Gas)
(a) Replacement w/gas water heaterX
(b) RepairX
(c) Change from LP gas to Natural Gas or from Natural Gas to LP gas per its listingX
(d) Adjustment and/or maintenanceX
(e) Replacement with electric water heaterX
(24) Windows
(a) Replacement in same opening with no structural changes*****X
(b) Replacement when structural changes are requiredX
(c) Replacement of glassX
(25) Wood Stove/Fireplace
(a) New installationX
(b) ReplacementX
(c) RepairX
(d) Adjustment and/or maintenanceX

*May also require a plan review. Please contact your local L&I representative.

** May also require a plan review. The department has detailed drawings you may use for openings in sidewalls. Please contact your local L&I representative.

***Fixtures include: Faucets, sinks, lavatories, laundry tubs, water closets (toilets), tubs, showers and tub/shower combos. A permit is not required for replacement of a like fixture as long as there are no changes to the existing water or drain lines.

****Fixtures must be installed per its listing and intended use.

*****Windows in bedrooms must be of egress type.

******Meter bases may only be installed by the manufacturer of the home unless repaired or replaced.

Note: Exemption from the permit and inspection requirements shall not be deemed to grant authorization for any work to be done in violation of the applicable code, chapter 296-150M WAC.

Wash. Admin. Code § 296-150M-0302

Amended by WSR 16-01-163, Filed 12/22/2015, effective 2/1/2016

Statutory Authority: Chapter 43.22 RCW and 2005 c 399. 05-24-020, § 296-150M-0302, filed 11/29/05, effective 1/1/06. Statutory Authority: Chapter 43.22 RCW and 2003 c 291. 05-01-102, § 296-150M-0302, filed 12/14/04, effective 2/1/05. Statutory Authority: RCW 43.22.340, 43.22.400, 43.22.432, 43.22.433, 43.22.434, 43.22.480, and 43.22.485, 2002 c 268, and chapter 43.22 RCW. 03-12-044, § 296-150M-0302, filed 5/30/03, effective 5/30/03. Statutory Authority: RCW 43.22.340, 43.22.350, 43.22.432, 43.22.434, 43.22.440, and 2001 c 335. 02-03-048, § 296-150M-0302, filed 1/9/02, effective 1/9/02.