Utah Admin. Code 645-301-200

Current through Bulletin No. 2024-21, November 1, 2024
Section R645-301-200 - Soils

The regulations in R645-301-200 present the minimum requirements for information on soil resources which will be included in each permit application.

210. Introduction.
211. The applicant will present a description of the premining soil resources as specified under R645-301-221. Topsoil and subsoil to be saved under R645-301-232 will be separately removed and segregated from other material.
212. After removal, topsoil will be immediately redistributed in accordance with R645-301-242, stockpiled pending redistribution under R645-301-234, or if demonstrated that an alternative procedure will provide equal or more protection for the topsoil, the Division may, on a case-by-case basis, approve an alternative.
220. Environmental Description.
221. Prime Farmland Investigation. All permit applications, whether or not Prime Farmland is present, will include the results of a reconnaissance inspection of the proposed permit area to indicate whether Prime Farmland exists as given under R645-302-313.
222. Soil Survey. The applicant will provide adequate soil survey information for those portions of the permit area to be affected by surface operations incident to UNDERGROUND COAL MINING and RECLAMATION ACTIVITIES and for the permit area of SURFACE COAL MINING and RECLAMATION ACTIVITIES consisting of the following:
222.100. A map delineating different soils;
222.200. Soil identification;
222.300. Soil description; and
222.400. Present and potential productivity of existing soils.
223. Soil Characterization. The survey will meet the standards of the National Cooperative Soil Survey as incorporated by reference in R645-302-314.100.
224. Substitute Topsoil. Where the applicant proposes to use selected overburden materials as a supplement or substitute for topsoil, the application will include results of analyses, trials, and tests as described under R645-301-232.100 through R645-301-232.600, R645-301-234, R645-301-242, and R645-301-243. The Division may also require the results of field-site trials or greenhouse tests as required under R645-301-233.
230. Operation Plan.
231. General Requirements. Each permit application will include a:
231.100. Description of the methods for removing and storing topsoil, subsoil, and other materials;
231.200. Demonstration of the suitability of topsoil substitutes or supplements;
231.300. Testing plan for evaluating the results of topsoil handling and reclamation procedures related to revegetation; and
231.400. Narrative that describes the construction, modification, use and maintenance of topsoil handling and storage areas.
232. Topsoil and Subsoil Removal.
232.100. All topsoil will be removed as a separate layer from the area to be disturbed, and segregated.
232.200. Where the topsoil is of insufficient quantity or poor quality for sustaining vegetation, the materials approved by the Division in accordance with R645-301-233.100 will be removed as a separate layer from the area to be disturbed, and segregated.
232.300. If topsoil is less than six inches thick, the operator may remove the topsoil and the unconsolidated materials immediately below the topsoil and treat the mixture as topsoil.
232.400. The Division may not require the removal of topsoil for minor disturbances which:
232.410. Occur at the site of small structures, such as power poles, signs, or fence lines; or
232.420. Will not destroy the existing vegetation and will not cause erosion.
232.500. Subsoil Segregation. The Division may require that the B horizon, C horizon, or other underlying strata, or portions thereof, be removed and segregated, stockpiled, and redistributed as subsoil in accordance with the requirements of R645-301-234 and R645-301-242 if it finds that such subsoil layers are necessary to comply with the revegetation requirements of R645-301-353 through R645-301-357.
232.600. Timing. All material to be removed under R645-301-232 will be removed after the vegetative cover that would interfere with its salvage is cleared from the area to be disturbed, but before any drilling, blasting, mining, or other surface disturbance takes place.
232.700. Topsoil and subsoil removal under adverse conditions. An exception to the requirements of R645-301-232 to remove topsoil or subsoils in a separate layer from an area to be disturbed by surface operations may be granted by the Division where the operator can demonstrate;
232.710. The removal of soils in a separate layer from the area by the use of conventional machines would be unsafe or impractical because of the slope or other condition of the terrain or because of the rockiness or limited depth of the soils; and
232.720. That the requirements of R645-301-233 have been or will be fulfilled with regard to the use of substitute soil materials unless no available substitute material can be made suitable for achieving the revegetation standards of R645-301-356, in which event the operator will, as a condition of the permit, be required to import soil material of the quality and quantity necessary to achieve such revegetation standards.
233. Topsoil Substitutes and Supplements.
233.100. Selected overburden materials may be substituted for, or used as a supplement to topsoil if the operator demonstrates to the Division that the resulting soil medium is equal to, or more suitable for sustaining vegetation on nonprime farmland areas than the existing topsoil, has a greater productive capacity than that which existed prior to mining for prime farmland reconstruction, and results in a soil medium that is the best available in the permit area to support revegetation.
233.200. The suitability of topsoil substitutes and supplements will be determined on the basis of analysis of the thickness of soil horizons, total depth, texture, percent coarse fragments, pH, and areal extent of the different kinds of soils. The Division may require other chemical and physical analyses, field-site trials, or greenhouse tests if determined to be necessary or desirable to demonstrate the suitability of topsoil substitutes or supplements.
233.300. Results of physical and chemical analyses of overburden and topsoil to demonstrate that the resulting soil medium is equal to or more suitable for sustaining revegetation than the available topsoil, provided that field-site trials, and greenhouse tests are certified by an approved laboratory in accordance with any one or a combination of the following sources:
233.310. NRCS published data based on established soil series;
233.320. NRCS Technical Guides;
233.330. State agricultural agency, university, Tennessee Valley Authority, Bureau of Land Management of U.S. Department of Agriculture Forest Service published data based on soil series properties and behavior; or
233.340. Results of physical and chemical analyses, field-site trials, or greenhouse tests of the topsoil and overburden materials (soil series) from the permit area.
233.400. If the operator demonstrates through soil survey or other data that the topsoil and unconsolidated material are insufficient and substitute materials will be used, only the substitute materials must be analyzed in accordance with R645-301-233.300.
234. Topsoil Storage.
234.100. Materials removed under R645-301-232.100, R645-301-232.200, and R645-301-232.300 will be segregated and stockpiled when it is impractical to redistribute such materials promptly on regraded areas.
234.200. Stockpiled materials will:
234.210. Be selectively placed on a stable site within the permit area;
234.220. Be protected from contaminants and unnecessary compaction that would interfere with revegetation;
234.230. Be protected from wind and water erosion through prompt establishment and maintenance of an effective, quick growing vegetative cover or through other measures approved by the Division; and
234.240. Not be moved until required for redistribution unless approved by the Division.
234.300. Where long-term disturbed areas will result from facilities and preparation plants and where stockpiling of materials removed under R645-301-232.100 would be detrimental to the quality or quantity of those materials, the Division may approve the temporary distribution of the soil materials so removed to an approved site within the permit area to enhance the current use of that site until needed for later reclamation, provided that:
234.310. Such action will not permanently diminish the capability of the topsoil of the host site; and
234.320. The material will be retained in a condition more suitable for redistribution than if stockpiled.
240. Reclamation Plan.
241. General Requirements. Each permit application will include plans for redistribution of soils, use of soil nutrients and amendments and stabilization of soils.
242. Soil Redistribution.
242.100. Topsoil materials removed under R645-301-232.100, R645-301-232.200, and R645-301-232.300 and stored under R645-301-234 will be redistributed in a manner that:
242.110. Achieves an approximately uniform, stable thickness consistent with the approved postmining land use, contours, and surface-water drainage systems;
242.120. Prevents excess compaction of the materials; and
242.130. Protects the materials from wind and water erosion before and after seeding and planting.
242.200. Before redistribution of the materials removed under R645-301-232 the regraded land will be treated if necessary to reduce potential slippage of the redistributed material and to promote root penetration. If no harm will be caused to the redistributed material and reestablished vegetation, such treatment may be conducted after such material is replaced.
242.300. The Division may not require the redistribution of topsoil or topsoil substitutes on the approved postmining embankments of permanent impoundments or roads if it determines that:
242.310. Placement of topsoil or topsoil substitutes on such embankments is inconsistent with the requirement to use the best technology currently available to prevent sedimentation, and
242.320. Such embankments will be otherwise stabilized.
243. Soil Nutrients and Amendments. Nutrients and soil amendments will be applied to the initially redistributed material when necessary to establish the vegetative cover.
244. Soil Stabilization.
244.100. All exposed surface areas will be protected and stabilized to effectively control erosion and air pollution attendant to erosion.
244.200. Suitable mulch and other soil stabilizing practices will be used on all areas that have been regraded and covered by topsoil or topsoil substitutes. The Division may waive this requirement if seasonal, soil, or slope factors result in a condition where mulch and other soil stabilizing practices are not necessary to control erosion and to promptly establish an effective vegetative cover.
244.300. Rills and gullies, which form in areas that have been regraded and topsoiled and which either:
244.310. Disrupt the approved postmining land use or the reestablishment of the vegetative cover, or
244.320. Cause or contribute to a violation of water quality standards for receiving streams will be filled, regraded, or otherwise stabilized; topsoil will be replaced; and the areas will be reseeded or replanted.
250. Performance Standards.
251. All topsoil, subsoil and topsoil substitutes or supplements will be removed, maintained and redistributed according to the plan given under R645-301-230 and R645-301-240.
252. All stockpiled topsoil, subsoil and topsoil substitutes or supplements will be located, maintained and redistributed according to plans given under R645-301-230 and R645-301-240.

Utah Admin. Code R645-301-200