Current through Register Vol. 54, No. 50, December 14, 2024
Section 73.43 - Pressurized distributionPressurized distribution is required in the following instances:
(1) All elevated sand mounds.(2) When the percolation rate exceeds 60 minutes/inch.(3) All systems having a total absorption area in excess of 2,500 square feet.(4) Individual residential spray irrigation system spray fields and buried sand filters.The provisions of this § 73.43 adopted August 2, 1971, effective 8/14/1971, 1 Pa.B. 1649; amended August 30, 1974, effective 9/16/1974, 4 Pa.B. 1805; amended January 21, 1983, effective 1/22/1983, 13 Pa.B. 508; amended November 7, 1997, effective 11/8/1997, 27 Pa.B. 5877.The provisions of this § 73.43 amended under section 9 of the Pennsylvania Sewage Facilities Act (35 P. S. § 750.9); The Clean Streams Law (35 P. S. §§ 691.1-691.1001); and section 1920-A of The Administrative Code of 1929 (71 P. S. § 510-20).
This section cited in 25 Pa. Code § 73.42 (relating to gravity distribution); 25 Pa. Code § 73.46 (relating to dosing pumps); and 25 Pa. Code § 73.161 (relating to general).