Current through Register Vol. 54, No.43, October 26, 2024
Section 71.63 - Retaining tanks(a) Retaining tanks are designed and constructed to facilitate ultimate disposal of the sewage at another site. This requires the control of retaining tanks through specific restrictions on their use.(b) General requirements for retaining tank use are as follows: (1) The official plan or revision shall meet the requirements of Subchapters B and C (relating to official plan requirements; and new land development plan revisions).(2) Proposed disposal sites, the method of disposal and the retaining tank cleaner for retaining tank waste shall be approved by the Department in a manner consistent with the Solid Waste Management Act (35 P. S. §§ 6018.101-6018.1003) prior to approval of the official plan or revision allowing the use of retaining tanks.(3) A municipality, sewer authority or sewage management agency may delegate or contract for the collection and disposal of the contents of the retaining tanks except that the ultimate responsibility for the proper collection and disposal of the contents shall remain with the municipality, authority or agency.(4) Whenever the local agency issues permits for retaining tanks, the municipality or local agency may impose other conditions it deems necessary for operation and maintenance of the tanks to prevent a nuisance or a public health hazard.(c) Holding tanks require regular service and maintenance to prevent their malfunction and overflow and shall be used in lieu of other methods of sewage disposal only when the following additional conditions are met:(1) The applicable official plan or revision thereto indicates the use of holding tanks for that lot and provides for replacement by adequate sewerage services in accordance with a schedule approved by the Department.(2) The applicable official plan or revision includes municipal financial assurances of the replacement project's implementation, such as public financing, bonding or other security of sufficient present value to assure completion or other assurances either singularly or in combination that the Department deems necessary.(3) The municipality, sewer authority or other Department approved entity with jurisdiction or responsibility over the site has by suitable ordinance, regulation or restriction assumed full responsibility for maintaining existing and new holding tanks. The ordinances, regulations or restrictions shall, as a minimum, include: (i) Identification of the administrative entity to receive, review and retain pumping receipts from permitted holding tanks.(ii) An annual inspection of holding tanks within the municipality with completion and retention of a written inspection report.(iii) Procedures and penalties for correction of malfunctions or public health hazards from holding tanks.(d) The restrictions in subsection (c)(1)-(3) do not apply to holding tanks when the local agency, municipality or the Department determines that the use is necessary to abate a nuisance or public health hazard.(e) The restrictions in subsection (c)(1) and (2) do not apply to holding tanks when the use is for institutions, recreational vehicle dump stations or commercial establishments with a sewage flow of less than 800 gpd.(f) A privy or chemical toilet is designed to receive sewage where there is no water under pressure and no piped wastewater. Privies shall be used in lieu of other methods of sewage disposal only when the following conditions are met:(1) The applicable official plan or the revision thereto indicates the use of privies for that lot and documents that soil and site suitability testing of that lot under §§ 73.11-73.16 has been conducted, and the site meets the requirements for the ultimate sewage disposal by one of the systems described under §§ 73.51-73.55 and 73.167 (relating to construction of absorption areas; and spray fields) to assure that adequate sewage facilities will be available to that lot in the future.(2) The municipality, sewer authority or other Department approved entity with jurisdiction or responsibility over the site has by suitable ordinance, regulation or restriction assumed responsibility for assuring the removal of a privy and the installation of an approved onlot sewage disposal system when water under pressure or piped water is available to the lot or when the property owner installs water under pressure or piped water or plumbing to move wastewater from the structure to the privy vault or to an unpermitted disposal system on that lot.(g) The restrictions in subsection (f) do not apply:(1) To a privy or chemical toilet when proposed for use on a lot of record in existence prior to May 15, 1972, which is 1 acre or larger and is not served now and will not be served in the future by water under pressure, piped water or plumbing to move wastewater from the structure to the privy vault or to an unpermitted disposal system on that lot.(2) To temporary use of portable retention tanks or portable chemical toilets when their use is proposed at construction sites or at the site of public gathering and entertainments.The provisions of this §71.63 adopted August 30, 1974, effective 9/16/1974, 4 Pa.B. 1805; amended February 28, 1975, effective 3/17/1975, 5 Pa.B. 374; reserved January 9, 1987, effective 1/10/1987, 17 Pa.B. 172; amended June 9, 1989, effective 6/10/1989, 19 Pa.B. 2429; amended November 7, 1997, effective 11/8/1997, 27 Pa.B. 5877.The provisions of this §71.63 amended under section 9 of the Pennsylvania Sewage Facilities Act (35 P. S. § 750.9); The Clean Streams Law (35 P. S. §§ 691.1-691.1001); and section 1920-A of The Administrative Code of 1929 (71 P. S. § 510-20).
This section cited in 25 Pa. Code § 73.11 (relating to general).