Section 252:515-17-2 - Run-on/run-off control systemsAll active land disposal facilities shall be designed, constructed, and maintained with:
(1) a run-on control system to prevent flow onto active portions of the facility during the peak discharge from a 24-hour, 25-year storm; and(2) a run-off control system with sufficient capacity to collect and control all contaminated stormwater resulting from a 24-hour, 25-year storm.Okla. Admin. Code § 252:515-17-2