S = 1300 - 20L/D
Maximum ratio L/D = 50
Where: L = Length, unsupported, in inches
D = Least side of the timber in inches
S = Allowable stress in pounds per square inch of cross-section.
Ohio Admin. Code 4123:1-3-13
Five Year Review (FYR) Dates: 10/29/2019 and 01/01/2025
Promulgated Under: 119.03
Statutory Authority: 4121.12, 4121.121, 4121.13, Const. Art. II, Sec. 35
Rule Amplifies: 4121.47
Prior Effective Dates: 04/01/1968, 11/01/1979, 04/01/1999, 01/01/2011