where:
The percent oxygen and percent carbon dioxide shall be determined by using the integrated or grab sampling and analysis procedures of method 3, 3A, 3B, or 3C, as appropriate, by traversing the duct at the same sampling locations used for each run of method 5.
Qs = volumetric flow rate of the total effluent in dscf/hr and
c = particulate concentration in lb/dscf.
N.D. Admin Code 33.1-15-05-04
General Authority: NDCC 23.1-06-04; S.L. 2017, ch. 199, § 1
Law Implemented: NDCC 23.1-06-04; S.L. 2017, ch. 199, § 21