The shell or drum of a boiler in which a lap seam crack is discovered along a longitudinal riveted joint must be immediately discontinued from use. If the boiler is not more than fifteen years of age, a complete new course of the original thickness may be installed at the discretion of the chief inspector. Patching is prohibited. "Lap seam crack" means the typical crack frequently found in lap seams, extending parallel to the longitudinal joint and located either between or adjacent to rivet holes.
N.D. Admin Code 33.1-14-03-05
General Authority: NDCC 23.1-16
Law Implemented: NDCC 23.1-16