Current through Register Vol. 46, No. 53, December 31, 2024
Section 80-7.6 - Apparatus required(a) Test cabinet. A test cabinet similar to that shown in Figure IV shall be used.(b) Support frame. A support frame conforming to Figure II shall be used. It shall be constructed of 1/8 inch steel.(c) Hold-down plate. A hold-down plate conforming to Figure III shall be used. It shall be constructed of 1/8 inch steel.(d) Spacers and clamps. A spacer and clamping arrangement shall be used which is capable of positioning the hold-down plate with its bottom surface one inch above the top surface of the support frame, so that it holds the test specimen at a one-inch thickness on the two sides and the back.(e) Thread. #50 white mercerized cotton thread.(f) Tape. Tape for fastening the thread to the frame. Note:Alternate methods of accomplishing this, such as small clips, may also be used.
(g) Weights. Weights for attachment to the timing threads. Note:Small clamp-type paper clips work well as weights.
(h) Burner. A Bunsen burner with a tube of 3/8 inch inside diameter shall be used. The gas adjusting valve is set to provide a flame, with the tube vertical, 11/2 inches in height. The air inlet to the burner is closed.(i) Gas. The gas used shall be Matheson Manufactured Gas Type B or equivalent.(j) Stop watch. A stop watch or other timing device shall be used capable of measuring the burning time to 0.2 second.N.Y. Comp. Codes R. & Regs. Tit. 12 §§ 80-7.6