N.J. Admin. Code § 19:38-3.5

Current through Register Vol. 56, No. 21, November 4, 2024
Section 19:38-3.5 - Determination of Project Rating
(a) A firm's Project Rating for the trade shall be determined by the following:

A [times] (100% + B + C + D) [times] E

where:

A = the firm's largest completed project in a specific trade listed in the Project Rating Proposal

B = the sum of the Reference Adjustment calculated pursuant to this chapter

C = the Safety Adjustment calculated pursuant this chapter

D = the Prevailing Wage Adjustment calculated pursuant to this chapter

E = the average of the firm's Project Evaluations

A firm's Project Rating for a trade cannot exceed the firm's Aggregate Rating and cannot exceed 170 percent of the firm's largest listed completed project.

(b) Reference Adjustment Calculation: A firm will be required to list in its Project Rating Proposal a minimum of two projects completed within the past seven years. The firm shall also provide project contacts for those projects. The Authority shall select, at its discretion, two projects to be confirmed and shall contact the owner's contact identified by the firm. If the Authority cannot contact an owner's contact, the Authority will contact the firm for another owner's contact for that project. If the firm is unable to provide an additional owner's contact, or if the Authority is unable to contact the additional owner's contact provided by the firm, the Authority will not use that project in the determination of the firm's Project Rating. The Authority will confirm the firm's performance on the job and assign a percentage value to the responses received. Project contacts will be asked if the performance in each of the following seven categories "exceeded expectations," "met expectations," or fell "below expectations" and the Authority will assign to the response the percentage adjustment listed below:

$ JExceeded,Met,BelowExpectationsExpectationsExpectations
$
Safety+5 percent+3 percent-5 percent
Quality of the+5 percent+2 percent-5 percent
construction.
Timeliness of the work+2 percent+1 percent-2 percent
performed.
Efficiency of the firm's+2 percent+1 percent-2 percent
contract administration.
Supervision of+2 percent+1 percent-2 percent
subcontractors.
Firm's level of+2 percent+1 percent-2 percent
cooperation during
construction.
Timeliness and+2 percent+1 percent-2 percent
efficiency of punch list
work corrections.

1. If an owner's contact rates a firm "below expectations" in either safety or quality of construction, or if the project reference adjustment is -5 or lower, the Authority will not use that project in the determination of the firm's Project Rating.
2. The Authority will total the project reference adjustments together and the sum shall be the Reference Adjustment. This Reference Adjustment shall be used as "B" in the calculation of the firm's Project Rating in (a) above.
(c) Bidders shall provide mandatory safety information as follows:
1. The firm will be required to list its most recent New Jersey Workers Compensation Insurance Experience Modification Rate (NJEMR) on its Project Rating Proposal. For any firm that has not performed work in New Jersey prior to the submission of this Project Rating Proposal, or for which the NJEMR has not been calculated, the firm will be required to submit its most recent Experience Modification Rate (EMR) for all other States for which it has performed work. The Authority will then calculate the average of the other states' EMRs. Where appropriate, the firm's NJEMR or its average EMR as calculated by the Authority will be assigned a percentage value as listed below:

EMR is less than or equal to .80+30 percent
EMR is greater than .80 but less than or equal to .90+20 percent
EMR is greater than .90 but less than or equal to+10 percent
1.00
EMR is greater than 1.00 but less than or equal to-10 percent
1.10
EMR is greater than 1.10 but less than or equal to-20 percent
1.20
EMR is greater than 1.20-40 percent

2. The firm shall be required to list safety information in its Project Rating Proposal. The safety information supplied will be assigned a percentage value as listed below:

Employee of the firm completed an+2 percent0 percent
OSHA 500 or OSHA 502 course in last 4
years.
Employee of the firm completed+2 percent0 percent
Council on Certification of Health,
Environmental and Safety Technologists
(CCHEST) "Safety Trained Supervisor in
Construction" course.
Employee of the firm completed+2 percent0 percent
Associated General Contractors of
America (AGCA) "Safety Management
Training Course."

The percentage value for the EMR and the percentage value for the Safety Information shall be added together and this total shall be the Safety Adjustment. The Safety Adjustment shall be used as "C" in the calculation of the firm's Project Rating in (a) above.

(d) Prevailing Wage: The firm will be required to list its prevailing wage record with the New Jersey Department of Labor and Workforce Development on its Project Rating Proposal. The Authority will assign a prevailing wage percentage value as listed below:

The firm has been adjudicated as having committed the following prevailing wage rate violations during the past five years:

None0 percent
One-10 percent
More than one-20 percent

This percentage value shall be the Prevailing Wage Adjustment. The Prevailing Wage Adjustment shall be used as "D" in the calculation of the firm's Project Rating in (a) above.

(e) Project Evaluations: Every construction project managed by the Authority will be evaluated by two evaluators for the following: quality of work; scheduling; management; cost control and change orders; safety and industrial hygiene; subcontractors; small business goals; and close-out.
1. Evaluation rating values are:
i. Outstanding (O) or 100 percent - far exceeds the contract requirements by consistently exhibiting excellent performance. Typically meets and regularly exceeds the contract requirements;
ii. Very Good (VG) or 90 percent - often exceeds the contract requirements and frequently provides a high level of performance. Typically meets and often exceeds the contract requirements;
iii. Satisfactory (S) or 80 percent - provides an acceptable level of performance consistently meeting the contract requirements;
iv. Marginal (M) or 70 percent for scheduling, management, cost control and change orders, subcontractors, close out and 40 percent for quality of work, safety and industrial hygiene, and small business goals - performs slightly below the requirements of the contract, meeting the contract requirements on an intermittent basis; and
v. Unsatisfactory (U) or 60 percent for scheduling, management, cost control and change orders, subcontractors, close out and 20 percent for quality of work, safety and industrial hygiene, and small business goals - fails to meet important contract requirements, resulting in a negative impact on the entire project.
2. The contractor's Performance Evaluation Summary Rating shall be the mathematical average of the two evaluators' ratings. In the event that there are multiple Performance Evaluation Summary Ratings for a contractor, the contractor's Performance Evaluation Summary Rating shall be the mathematical average of all Performance Evaluation Summary Ratings.
3. The Authority will assign a Project Evaluation Performance Multiplier as listed below:

Performance Evaluation Summary RatingPerformance multiplier
80 points or higher1.00
70 points to 79.9 points.50
69.9 points or lower.25

This Performance Multiplier shall be used as "E" in the calculation of the firm's Project Rating. In the event that a contractor does not have a Performance Evaluation Summary Rating, the Authority will disregard the Performance Multiplier in the calculation of the firm's Project Rating in (a) above.

N.J. Admin. Code § 19:38-3.5

Amended by R.2014 d.001, effective 1/6/2014.
See: 45 N.J.R. 1592(a), 46 N.J.R. 131(a).
Substituted "Authority" for "Corporation" throughout; and in the introductory paragraph of (b), inserted a comma following "met expectations".