Final treatment and dispersal must be according to applicable design requirements in chapter 7080, except as modified in this part. Code of Federal Regulations, title 40, parts 144 and 146, prescribe additional design regulations applicable to certain systems designed under this chapter. At a minimum, flow amounts to be used for the purposes of this part must be derived from part 7081.0110.
MSTS components must meet the setbacks in Table II.
Table II | |||
Minimum Setback Distances (feet) | |||
Feature | Sewage Tank, Holding Tank, or Sealed Privy | Absorption Area or Sealed Privy | Building Sewer or Sewage Supply Pipes |
Water supply wells | * | * | * |
Buried water lines | * | * | * |
Buildings** | 10 | 20 | |
System site boundaries | 10 | 10 | |
The ordinary high water level of public waters | *** | *** |
*Setbacks from buried water pipes and water supply wells are governed by chapters 4714 and 4725, respectively.
**If setbacks are reduced through local administrative processes, the system shall not be located under or within the structure.
***Setbacks from lakes, rivers, and streams are governed by chapters 6105 and 6120.
The site proposed to support the soil treatment and dispersal system must:
Inspection pipes must be located to adequately assess the hydraulic performance of the entire soil dispersal system.
The system geometry and lawn area sizing shall be sized to prevent groundwater mounding from violating the unsaturated zone beneath the soil system according to subpart 7, for proper hydraulic functioning, and for concentration reduction of nitrogen and phosphorus, if applicable.
Additional set-aside land area of 100 percent of the size determined in subpart 6 is required for systems whose absorption area receives effluent meeting treatment level A or B in part 7083.4030 or designed in accordance with part 7080.2400. Additional land area of 50 percent of the size determined in subpart 6 is required for systems whose absorption area receives treatment level C in part 7083.4030. The reserve land area must be identified and protected for future use if necessary. Replacement MSTS proposed on sites that cannot meet this requirement are allowed to be exempted by the local unit of government.
For treatment of effluent by soil to meet the performance criteria in part 7081.0080, subpart 4, item C, the soil treatment and dispersal systems must meet the requirements of item A, B, or C.
Systems must employ nitrogen mitigation methods to achieve compliance with part 7081.0080, subpart 4, item D, and must be monitored in accordance with part 7081.0210, subpart 4.
Phosphorus mitigation methods must be employed to achieve compliance with part 7081.0080, subpart 4, item E, if natural processes are found inadequate.
All information required in this part shall be submitted for review and approval by the local unit of government prior to system construction, including all applicable information delineated on a map.
Minn. R. agency 167, ch. 7081, pt. 7081.0270
Statutory Authority: MS s 115.03; 115.55