Current through Register Vol. 49, No. 20, November 12, 2024
Part 1305.1510 - SECTION 1510, REROOFING IBC Section 1510.5 is amended to read as follows:
1510.5 Reinstallation of materials. Existing slate, clay or cement tile shall be permitted for reinstallation, except that damaged, cracked or broken slate or tile shall not be reinstalled. Existing vent flashing, metal edging, drain outlets, collars and metal counterflashings shall not be reinstalled where rusted, damaged or deteriorated. Aggregate surfacing materials shall not be reinstalled unless such aggregate complies with the gradation requirements of ASTM C-33 Standard Specification for Concrete Aggregate.Minn. R. agency 151, ch. 1305, pt. 1305.1510
27 SR 1474; L 2007 c 140 art 4 s 61; art 13 s 4Statutory Authority: MS s 16B.59; 16B.61; 16B.64; 326B.101; 326B.106; 326B.13