Mich. Admin. Code R. 408.41976

Current through Vol. 24-21, December 1, 2024
Section R. 408.41976 - Controls

Rule 1976.

(1) When a presence-sensing device is used as a safety device, the control shall incorporate a fail-safe feature.
(2) Machine start controls shall be designed and installed or guarded to prevent unintentional activation by contact with objects or a part of the body.
(3) A machine shall be provided with a stop device that is within the reach of the operator's designated position.
(4) A foot control shall be provided with a cover or guard to prevent accidental activation.