Parameter | Limitation |
Moisture Content | < 50% (by weight) or zero free moisture |
pH* | 6.5 - 9.0 |
Electrical Conductivity (EC) | 8 mmhos/cm |
Sodium Adsorption Ratio (SAR) | 12 |
Exchangeable Sodium Percentage (ESP) | 15% |
Total Barium: Reuse at Location other than Commercial facility | 40,000 ppm |
Leachate Testing** for: TPH Chlorides | 10.0 mg/l 500.0 mg/l |
TCLP Benzene | 0.5 mg/l |
Leachate Testing**: Arsenic Barium Cadmium Chromium Copper Lead Mercury Molybdenum Nickel Selenium Silver Zinc | 0.5 mg/l 10.0 mg/l 0.1 mg/l 0.5 mg/l 0.5 mg/l 0.5 mg/l 0.02 mg/l 0.5 mg/l 0.5 mg/l 0.1 mg/l 0.5 mg/l 5.0 mg/l |
NORM | Not to exceed Applicable DEQ Criteria/Limits |
*E and P Waste when chemically treated (fixated) shall, in addition to the criteria set forth be acceptable as reusable material with a pH range of 6.5 to 12 and an electrical conductivity of up to 50 mmhos/cm, provided such reusable material passes leachate testing requirements for chlorides in §565. F above and leachate tests for metals in §565. F above.
**The leachate testing method for TPH, chlorides and metals is included in the Laboratory Manual for the Analysis of E and P Waste (Department of Natural Resources, August 9, 1988, or latest version).
La. Admin. Code tit. 43, § XIX-565