Current through Register Vol. 43, No. 46, November 14, 2024
Section 28-24-10 - Cleaning and disinfecting nonelectrical instruments and equipment(a) Each practitioner shall perform the following after each service as applicable: (1) Clean each nonelectrical instrument or nonelectrical piece of equipment;(2) rinse the instrument or equipment with potable water; and(3) use one of the following disinfection methods:(A) For instruments and equipment other than shears and makeup brushes, perform one of the following:(i) Totally immerse the instrument or equipment in a disinfectant and disinfect according to the manufacturer's instructions and then rinse the instrument or equipment with potable water; or(ii) totally immerse the instrument or equipment in bleach solution for 10 minutes and then rinse the instrument or equipment with potable water;(B) for shears, use a concentrate, spray, wipe, or foam disinfectant according to the manufacturer's instructions; and(C) for makeup brushes, use a concentrate, spray, or foam disinfectant according to the manufacturer's instructions.(b) Each practitioner shall ensure that the disinfectant or bleach solution specified in subsection (a) is prepared, available for use, and covered at all times. Disinfectants and bleach solutions shall be changed daily or more often if the disinfectant or bleach solution becomes visibly cloudy or dirty.(c) For each disinfectant used as specified in subsection (a), the following shall be available at all times in the establishment or school and shall be provided upon request to the board or the board's designee:(2) the manufacturer-labeled container with sufficient disinfectant or bleach solution to ensure safe services.(d) Each nonelectrical instrument and each nonelectrical piece of equipment that has been used on a consumer or soiled in any manner shall be placed in a labeled, covered container until the instrument or piece of equipment is cleaned and disinfected.(e) All disinfected nonelectrical instruments and all disinfected nonelectrical pieces of equipment shall be stored in a labeled and clean, enclosed cabinet, drawer, or covered container reserved for clean instruments only.(f) The electrolysis instruments and pieces of equipment that are sterilized in accordance with K.A.R. 28-24-12 shall not be subject to the requirements of this regulation.Kan. Admin. Regs. § 28-24-10
Authorized by and implementing K.S.A. 65-1,148; effective Jan. 4, 1993; amended Oct. 5, 2007; amended by Kansas Register Volume 39, No. 13 ; effective 4/10/2020.