675 Ind. Admin. Code 16-1.4-4

Current through November 6, 2024
Section 675 IAC 16-1.4-4 - Chapter 3; general regulations

Authority: IC 22-13-2

Affected: IC 22-12; IC 22-13; IC 22-14; IC 22-15; IC 36-7-2-9

Sec. 4.

Chapter 3 is amended as follows:

(a) Amend Section 301.1.1 to read as follows: See Section 101.2.
(b) Amend Section 301.3 to add an exception to read as follows:

Exception: Bathtubs, showers, lavatories, clothes washers, air conditioning condensation, laundry trays, and process water that is exposed only to heat transfer and no other contamination shall not be required to discharge to the sanitary drainage system where such fixtures discharge to a gray water system in accordance with Appendix C.

(c) Amend Section 301.7 to read as follows: See Section 101.7.
(d) Amend Section 304.4 by deleting the text after "protected" and inserting "with an impervious material".
(e) Amend Section 305.3 by adding a third sentence to read as follows: No plumbing pipes shall be directly embedded in concrete or masonry.
(f) Amend Section 305.6 as follows:
(1) In the first sentence, delete "water".
(2) Delete the last sentence in its entirety without substitution.
(g) Delete the text of Section 305.6.1 and insert to read as follows: Waterlines. Waterlines shall not be installed outside of a building, in attics or crawlspaces, or in any other place subjected to freezing temperatures, unless adequate provision is made to protect such waterlines from freezing by insulation, ambient heat, or alternate heat source. No waterlines shall be concealed in outside walls, above grade.
(h) Add Section 305.6.2 to read as follows: The minimum depth of exterior water supply piping measured from finished grade to the top of the water pipe shall be in accordance with Table 305.6.2.
(i) Add Table 305.6.2 Minimum Depth of Bury of Exterior Water Supply Piping as follows:

Table 305.6.2

Minimum Depth of Bury for Exterior Water Supply Piping

NO. COUNTY DEPTH IN INCHES
1 Adams 48
2 Allen 48
3 Bartholomew 36
4 Benton 48
5 Blackford 42
6 Boone 42
7 Brown 36
8 Carroll 48
9 Cass 48
10 Clark 36
11 Clay 36
12 Clinton 42
13 Crawford 36
14 Daviess 36
15 Dearborn 36
16 Decatur 36
17 Dekalb 48
18 Delaware 42
19 Dubois 36
20 Elkhart 48
21 Fayette 42
22 Floyd 36
23 Fountain 36
24 Franklin 36
25 Fulton 48
26 Gibson 36
27 Grant 42
28 Greene 36
29 Hamilton 42
30 Hancock 42
31 Harrison 42
32 Hendricks 42
33 Henry 42
34 Howard 42
35 Huntington 48
36 Jackson 36
37 Jasper 48
38 Jay 42
39 Jefferson 36
40 Jennings 36
41 Johnson 42
42 Knox 36
43 Kosciusko 48
44 LaGrange 48
45 Lake 48
46 LaPorte 48
47 Lawrence 36
48 Madison 42
49 Marion 42
50 Marshall 48
51 Martin 36
52 Miami 48
53 Monroe 36
54 Montgomery 42
55 Morgan 42
56 Newton 48
57 Noble 48
58 Ohio 36
59 Orange 36
60 Owen 36
61 Parke 42
62 Perry 36
63 Pike 36
64 Porter 48
65 Posey 36
66 Pulaski 48
67 Putnam 42
68 Randolph 42
69 Ripley 36
70 Rush 42
71 St. Joseph 48
72 Scott 36
73 Shelby 42
74 Spencer 36
75 Starke 48
76 Steuben 48
77 Sullivan 36
78 Switzerland 36
79 Tippecanoe 42
80 Tipton 42
81 Union 42
82 Vanderburgh 36
83 Vermillion 42
84 Vigo 36
85 Wabash 48
86 Warren 42
87 Warrick 36
88 Washington 36
89 Wayne 42
90 Wells 48
91 White 48
92 Whitley 48

(j) Amend Section 305.8 to read as follows: delete "sixty two thousandths (0.062) -inch-thick (1.6 mm)" and insert "five hundred seventy-five ten-thousandths (0.0575) -inch-thick (1.463 mm), No. 16 gage".
(k) Delete Section 308.6 without substitution.
(l) Delete Section 311 in its entirety without substitution.
(m) Amend Section 312.9.1 to read as follows: Delete "annual" and insert "at the time of installation".
(n) Delete Section 312.9.2 without substitution.
(o) Amend Section 314.2.1 as follows:
(1) After "disposal", insert "gray water storage or other nonpotable sustainable use".
(2) Insert the following text after the first sentence: Such piping shall maintain a minimum horizontal slope in the direction of discharge of not less than one-eighth (1/8) unit vertical in twelve (12) units horizontal (one (1) percent slope).

675 IAC 16-1.4-4

Fire Prevention and Building Safety Commission; 675 IAC 6-1.4-4; filed Sep 25, 2012, 2:42 p.m.: 20121024-IR-675110448FRA, eff 90 days after filing with the Publisher
Readopted filed 7/3/2018, 2:22 p.m.: 20180801-IR-675180204RFA
Readopted filed 6/10/2024, 8:09 a.m.: 20240710-IR-675230794RFA