Current through Register Vol. 48, No. 45, November 8, 2024
Section 817.405 - Foundation Constructiona) If the in situ material provides insufficient strength to meet the requirements of Section 817.404, then the insufficient material shall be removed and replaced with clean materials sufficient to meet the requirements of Section 817.404.b) All trees, stumps, roots, boulders and debris shall be removed.c) All material shall be compacted to achieve the strength and density properties necessary to demonstrate compliance with this Part in conformance with a construction quality assurance plan pursuant to 35 Ill. Adm. Code 811.Subpart E.d) Placement of frozen soil or soil onto frozen ground is prohibited.e) The foundation shall be constructed and graded to provide a smooth, workable surface on which to construct the liner.Ill. Admin. Code tit. 35, § 817.405