Certain suppliers must monitor to determine compliance with the State-only MCLs in Section 611.300 and the revised MCLs in 611.301, as appropriate, as this Subpart N requires:
Contaminant | MCL (mg/L, except asbestos) | Method | Detection Limit (mg/L) | |
Antimony | 0.006 | Atomic absorption - furnace technique | 0.003 | |
Atomic absorption - furnace technique (stabilized temperature) | 0.00085 | |||
Inductively coupled plasma-mass spectrometry | 0.0004 | |||
Atomic absorption - gaseous hydride technique | 0.001 | |||
Arsenic | 0.010 | Atomic absorption - furnace technique | 0.001 | |
Atomic absorption - furnace technique (stabilized temperature) | 0.000056 | |||
Atomic absorption - gaseous hydride technique | 0.001 | |||
Inductively coupled plasma-mass spectrometry | 0.00147 | |||
Asbestos | 7 MFL1 | Transmission electron microscopy | 0.01 MFL | |
Barium | 2 | Atomic absorption - furnace technique | 0.002 | |
Atomic absorption - direct aspiration technique | 0.1 | |||
Inductively coupled plasma arc furnace | 0.002 | |||
Inductively coupled plasma | 0.001 | |||
Beryllium | 0.004 | Atomic absorption - furnace technique | 0.0002 | |
Atomic absorption - furnace technique (stabilized temperature) | 0.000025 | |||
Inductively coupled plasma2 | 0.0003 | |||
Inductively coupled plasma-mass spectrometry | 0.0003 | |||
Cadmium | 0.005 | Atomic absorption - furnace technique | 0.0001 | |
Inductively coupled plasma | 0.001 | |||
Chromium | 0.1 | Atomic absorption - furnace technique | 0.001 | |
Inductively coupled plasma | 0.007 | |||
Inductively coupled plasma | 0.001 | |||
Cyanide | 0.2 | Distillation, spectrophotometric3 | 0.02 | |
Automated distillation, spectrophotometric3 | 0.005 | |||
Distillation, selective electrode3 | 0.05 | |||
Distillation, amenable, spectrophotometric4 | 0.02 | |||
UV, distillation, spectrophotometric8 | 0.0005 | |||
Micro distillation, flow injection, spectrophotometric3 | 0.0006 | |||
Ligand exchange with amperometry4 | 0.0005 | |||
Mercury | 0.002 | Manual cold vapor technique | 0.0002 | |
Automated cold vapor technique | 0.0002 | |||
Nickel | No MCL | Atomic absorption - furnace technique | 0.001 | |
Atomic absorption - furnace technique (stabilized temperature) | 0.00065 | |||
Inductively coupled plasma2 | 0.005 | |||
Inductively coupled plasma-mass spectrometry | 0.0005 | |||
Nitrate (as N) | 10 | Manual cadmium reduction | 0.01 | |
Automated hydrazine reduction | 0.01 | |||
Automated cadmium reduction | 0.05 | |||
Ion-selective electrode | 1 | |||
Ion chromatography | 0.01 | |||
Capillary ion electrophoresis | 0.076 | |||
Nitrite (as N) | 1 | Spectrophotometric | 0.01 | |
Automated cadmium reduction | 0.05 | |||
Manual cadmium reduction | 0.01 | |||
Ion chromatography | 0.004 | |||
Capillary ion electrophoresis | 0.103 | |||
Selenium | 0.05 | Atomic absorption - furnace technique | 0.002 | |
Atomic absorption - gaseous hydride technique | 0.002 | |||
Thallium | 0.002 | Atomic absorption - furnace technique | 0.001 | |
Atomic absorption - furnace technique (stabilized temperature) | 0.00075 | |||
Inductively coupled plasma-mass spectrometry | 0.0003 | |||
Footnotes. | ||||
1 | "MFL" means millions of fibers per liter less than 10 µm. | |||
2 | Using a 2x preconcentration step as noted in USEPA 200.7(94). Lower MDLs are possible when using a 4x preconcentration. | |||
3 | Screening method for total cyanides. | |||
4 | Measures "free" cyanides when omitting distillation, digestion, or ligand exchange. | |||
5 | Lower MDLs are possible using stabilized temperature graphite furnace atomic absorption. | |||
6 | The MDL for USEPA 200.9(94) (atomic absorption-platform furnace (stabilized temperature)) possible using a 2x concentration step during sample digestion. The MDL using direct analyses (i.e., no sample digestion) is higher. Using multiple depositions, USEPA 200.9(94) can obtain an MDL of 0.0001 mg/L. | |||
7 | Using selective ion monitoring, USEPA 200.8(94) (ICP-MS) is capable of obtaining an MDL of 0.0001 mg/L. | |||
8 | Measures total cyanides when using UV-digestor, and "free" cyanides when bypassing UV-digestor. |
Ill. Admin. Code tit. 35, § 611.600
Amended at 37 Ill. Reg. 1978, effective February 4, 2013
BOARD NOTE: Subsections (a) through (c) derive from 40 CFR 141.23 preamble, and subsection (d) derives from 40 CFR 141.23 (a)(4)(i) and appendix A to subpart C of 40 CFR 141. See the Board Note at Section 611.301(b) relating to the MCL for nickel.