Current through Register Vol. 48, No. 49, December 6, 2024
Section 602.260 - Water Main Construction Applicationsa) Water main construction permit applications must specify the following: 1) the existing population served by the present supply, and the population to be served by the water main extension;2) the average daily pumpage for the community water supply on an annual basis;3) the maximum daily pumpage;4) the capacity of the community water supply;5) the capacity of the raw water source;6) the capacity of the proposed water main;7) the normal expected operating pressure on the proposed water main;8) the minimum expected operating pressure on the proposed water main;9) the pressure at the point of connection at present maximum demand;10) the calculated pressure at the point of connection under maximum demand after installation of the water main;11) the size of the pipe and total feet of the water main;12) the pipe material and type of joint;13) the proposed depth below ground surface of the water main;14) sewer and water separation: A) an indication of whether the minimum horizontal and vertical separation requirements in 35 Ill. Adm. Code 604.1440 have been met; andB) an explanation of other measures taken to protect the water main if the separation requirements are not met;15) a disinfection plan that details the chemical to be used, initial disinfectant concentration, final disinfectant concentration and retention time in hours; and16) a water sampling plan to meet the requirements of Section 602.310.b) The following information must be submitted on plans with water main construction permit applications: 1) the border lines of the municipality, water district or area to be served;2) the size, length and identity of proposed water mains and water system structures;3) the elevation of water mains where necessary to show proper separation from sewers and the elevation of other water system structures;4) the location of existing or proposed streets;5) the location of storm, sanitary, combined and house sewers, septic tanks, disposal fields and cesspools;6) the location of pipelines and other sources containing hydrocarbons;7) the distance between the community water supply structures and the sources of pollution listed in 35 Ill. Adm. Code 604.150(a);8) stream crossings with elevations of the stream bed shown, including the normal, extreme high and extreme low water levels of the stream; and9) all appurtenances, specific structures or equipment having any connection with planned water mains and water system structures.Ill. Admin. Code tit. 35, § 602.260
Added at 40 Ill. Reg. 6799, effective 4/15/2016Amended at 43 Ill. Reg. 8036, effective 7/26/2019