Ill. Admin. Code tit. 32 § 346.370

Current through Register Vol. 48, No. 45, November 8, 2024
Section 346.370 - Power Failures
a) If electrical power at a panoramic irradiator is lost for longer than 10 seconds, the sources shall automatically return to the shielded position.
b) The lock on the door of the radiation room of a panoramic irradiator shall not be deactivated by a power failure.
c) During a power failure, the area of any irradiator where the sources are located may be entered only when using an operable and calibrated radiation survey meter.
d) If non-electrical power is used to control or operate any irradiator safety feature, failure of that power source shall automatically return the radiation sources to their fully shielded position.

Ill. Admin. Code tit. 32, § 346.370