Haw. Code R. § 11-45-158

Current through November, 2024
Section 11-45-158 - Specific requirements for the use of sealed sources for diagnosis

A licensee authorized to use radioactive material as a sealed source for diagnostic purposes shall have available for use a portable radiation detection survey instrument capable of detecting dose rates over the range 0.1 millirem (one microsievert) per hour to fifty millirems (five hundred microsieverts) per hour or a portable radiation measurement survey instrument capable of measuring dose rates over the range one millirem (ten microsieverts) per hour to one thousand millirems (ten millisieverts) per hour. The instrument shall be operable and calibrated in accordance with section 11-45-141.

Haw. Code R. § 11-45-158

[Eff 11/12/99] (Auth: HRS §§ 321-10, 321-11, 321-71) (Imp: HRS §§ 321-1, 321-11(21), 321-71)