Current through Reg. 50, No. 244; December 17, 2024
Section 64E-5.1413 - Power Failures(1) If electrical power at a panoramic irradiator is lost for longer than 10 seconds, the sources must return automatically to the shielded position.(2) The lock on the door of the radiation room of a panoramic irradiator must not be deactivated by a power failure.(3) During a power failure, the area around the pool of an irradiator shall not be entered without using an operable and calibrated radiation survey meter.Fla. Admin. Code Ann. R. 64E-5.1413
Rulemaking Authority 404.051(4) FS. Law Implemented 404.051(1), (5), (6), 404.061, 404.081, 404.141 FS.
New 8-14-96, Formerly 10D-91.1513.New 8-14-96, Formerly 10D-91.1513.