1 Del. Admin. Code § 706-7-2.0

Current through Register Vol. 28, No. 5, November 1, 2024
Section 706-7-2.0 - Construction
2.1 Haunted Houses shall only be allowed to operate on the level of exit discharge as well as one story above the level of discharge.
2.2 Occupants shall be prohibited from areas not on the level of exit discharge or the story above it. Provisions shall be made to physically bar occupants from entering areas not on the level of exit discharge and areas not open to the public.
2.3 Haunted houses shall not be allowed in windowless buildings.
2.4 Walls and windows may use 1/4-inch plywood as covering (minimum standard). Walls are to consist of 3/8 inch plywood and/or drywall.
2.5 Foam rubber, urethane foam, or any other type of expanded combustible material known to burn readily shall not be permitted in the building. Black plastic (fire resistive only) or fire treated cloth may be used on walls.

1 Del. Admin. Code § 706-7-2.0