Conn. Agencies Regs. § 22-111j-5

Current through December 27, 2024
Section 22-111j-5 - Investigational allowances
(a) A commercial fertilizer, or any individual element contained therein, shall be deemed deficient if the analysis of nutrient is below the guarantee by an amount exceeding the values in the schedule below. Such guaranteed analysis shall be conducted in accordance with the recommended Association of Official Analytical Chemists (A.O.A.C.) procedures for obtaining samples and sample preparation. Such procedures are described in Official Methods of Analysis of the Association of Official Analytical Chemists, 11th edition, 1970, and in succeeding issues of the Journal of the Association of Official Analytical Chemists. Replicate data shall be evaluated by following the instructions listed in the Journal of the Association of Official Analytical Chemists, vol. 59, no. 5, pg. 935, table 19, October 1966.

Guarantee

Percent

Nitrogen

Percent

Available Phosphoric

Acid, Percent

Potash

Percent

04

0.49

0.67

0.41

05

0.51

0.67

0.43

06

0.52

0.67

0.47

07

0.54

0.68

0.53

08

0.55

0.68

0.60

09

0.57

0.68

0.65

10

0.58

0.69

0.70

12

0.61

0.69

0.79

14

0.63

0.70

0.87

16

0.67

0.70

0.94

18

0.70

0.71

1.01

20

0.73

0.72

1.08

22

0.75

0.72

1.15

24

0.78

0.73

1.21

26

0.81

0.73

1.27

28

0.83

0.74

1.33

30

0.86

0.75

1.39

32

0.88

0.76

1.44

(b) Secondary and minor elements shall be deemed deficient if any element is below the guarantee by an amount exceeding the values in the table below. The maximum allowable deviation of the values listed in such tables shall be one unit (1%).

Element

Allowable Deficiency

Calcium

0.2 unit + 5% of guarantee

Magnesium

0.2 unit + 5% of guarantee

Sulfur

0.2 unit + 5% of guarantee

Boron

0.003 unit + 15% of guarantee

Cobalt

0.0001 unit + 30% of guarantee

Molybdenum

0.0001 unit + 30% of guarantee

Chlorine

0.005 unit + 10% of guarantee

Copper

0.005 unit + 10% of guarantee

Iron

0.005 unit + 10% of guarantee

Manganese

0.005 unit + 10% of guarantee

Sodium

0.005 unit + 10% of guarantee

Zinc

0.005 unit + 10% of guarantee

(c) Method of determining investigational allowances. A minimum of two (2) values shall be averaged in order to determine that the minimum guarantee has been met. If more than two (2) values are obtained, all significant values shall be averaged. Each value may be "rounded" to one decimal place for easy recording, but each value shall be carried to two (2) decimal places in order to apply such established averages to the preceding table. If the requisite guarantee is not listed in such table, the necessary appropriate value shall be calculated by interpolation.
(d) Sampling. Wherever applicable, all sampling equipment used and procedures employed shal be those adopted by the Association of Official Analytical Chemists.

Conn. Agencies Regs. § 22-111j-5

Effective August 9, 1979