521 CMR, § 30.16

Current through Register 1536, December 6, 2024
Section 30.16 - CHILDREN'S SINK

Sinks including vanities shall comply with the following:

30.16.1Clear floor space: A clear floor space complying with 521 CMR 30.5, Clear Floor Space shall be provided in front of a sink to allow a forward approach. The clear floor space shall be on an accessible route and shall extend no more than a maximum of 19 inches (19" = 483mm) underneath the sink.
30.16.2 Height: Sinks shall be mounted with the rim no higher than 30 inches (30" = 762mm) above the finish floor. A clearance of at least 25 inches (25" = 635mm) above the finish floor to the bottom of the apron shall be provided. Knee and toe clearance shall be at least 30 inches (30"= 762mm) wide and 19 (19" = 483mm) deep.
30.16.3 Piping: Sink traps and drains shall be located as close to rear walls as possible. Hot water and drain pipes exposed under sinks shall be recessed, insulated, or guarded. There shall be no sharp or abrasive surfaces under sinks.
30.16.4 Faucets: Faucets shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. Lever-operated push-type, touch-type, or electronically controlled mechanisms are acceptable designs. If self- closing valves are used, the faucet shall remain open for at least ten seconds.

521 CMR, § 30.16