105 CMR, § 410.430

Current through Register 1536, December 6, 2024
Section 410.430 - Natural Light and Obstructions
(A) The owner shall provide transparent or translucent glass which admits unobstructed light from the outdoors equal in area to a minimum 8% of the entire floor area in:
(1) Habitable rooms other than a kitchen.
(2) Kitchens which have a floor area greater than 70 square feet.
(B) If any light obstructing structure is located less than three feet from the outside of and extends to a level above the lower level of the transparent or translucent glass, that portion so obstructed shall not be included as contributing to the required minimum total glass area.

105 CMR, § 410.430

Amended by Mass Register Issue 1495, eff. 5/12/2023.
Amended by Mass Register Issue 1497, eff. 5/12/2023.