47 C.F.R. § 15.241

Current through November 30, 2024
Section 15.241 - Operation in the band 174-216 MHz
(a) Operation under the provisions of this section is restricted to biomedical telemetry devices.
(b) Emissions from the device shall be confined within a 200 kHz band which shall lie wholly within the frequency range of 174-216 MHz.
(c) The field strength of any emissions radiated within the specified 200 kHz band shall not exceed 1500 microvolts/meter at 3 meters. The field strength of emissions radiated on any frequency outside of the specified 200 kHz band shall not exceed 150 microvolts/meter at 3 meters. The emission limits in this paragraph are based on measurement instrumentation employing an average detector. The provisions in § 15.35 for limiting peak emissions apply.

47 C.F.R. §15.241