43 C.F.R. § 3175.119

Current through October 31, 2024
Section 3175.119 - Components to analyze
(a) The gas must be analyzed for the following components:
(1) Methane;
(2) Ethane;
(3) Propane;
(4) Iso Butane;
(5) Normal Butane;
(6) Pentanes;
(7) Hexanes + (C6+);
(8) Carbon dioxide; and
(9) Nitrogen.
(b) When the concentration of C6+ exceeds 0.5 mole percent, the following gas components must also be analyzed:
(1) Hexanes;
(2) Heptanes;
(3) Octanes; and
(4) Nonanes +.
(c) In lieu of testing each sample for the components required under paragraph (b) of this section, the operator may periodically test for these components and adjust the assumed C6+ composition to remove bias in the heating value (see § 3175.126(a)(3) ). The C6+ composition must be applied to the mole percent of C6+ analyses until the next analysis is done under paragraph (b) of this section. The minimum analysis frequency for the components listed in paragraph (b) of this section is as follows:
(1) For high-volume FMPs, once per year; and
(2) For very-high-volume FMPs, once every 6 months.

43 C.F.R. §3175.119

81 FR 81609 , 1/17/2017